Bedienungsanleitung KXE - REITZ Ventilatoren
Bedienungsanleitung KXE - REITZ Ventilatoren
Bedienungsanleitung KXE - REITZ Ventilatoren
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />
Transport, Installation<br />
3.3.1 Load suspension devices � Fans are only to be lifted and transported with the<br />
appropriate hoists and means of transport (weight<br />
indication see fan data sheet or fan drawing).<br />
Figure 1<br />
transport and lifting lugs<br />
spread and inclination angle<br />
αN<br />
Figure 2<br />
αS<br />
load<br />
� Fasten sling devices only at the especially provided<br />
lifting lugs (see Figure 1)<br />
� Do not damage components or fan when fastening<br />
sling devices.<br />
� Do not fasten sling devices to the inlet, discharge,<br />
bearings, motor or base frame.<br />
This damages the fan and excludes and limits<br />
the liability of the manufacturer.<br />
� Sling devices must be of the same length. Pay<br />
attention to an even load distribution.<br />
� Observe the spread angle and the inclination angle<br />
(see Figure 2)<br />
The inclination angle αN must not exceed 60°,<br />
that is to say the spread angle αS must not exceed<br />
120°.<br />
� Wear personal protective equipment (see chapter<br />
2.9)<br />
3.3