7.4 Shaft seal<br />
7.4.1 Standard seal<br />
housing backplate<br />
felt ring<br />
impeller hub<br />
Figure 9<br />
7.4.2 Shaft seal with graphite ring<br />
Figure 10<br />
impeller<br />
BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />
Maintenance<br />
Depending on the individual requirements the fan can be<br />
equipped with different seal systems.<br />
Shaft seal with felt ring (up to 80°C)<br />
Shaft seal with Klingerit ring (from 80°C to 180°C)<br />
The seal with felt ring must be re-lubricated monthly. Apply a<br />
small quantity of lubrication oil into the clearance between<br />
the seal and shaft by oil can.<br />
The seal with Klingerit ring does not require re-lubrication.<br />
Figure 9 � presentation of shaft seal<br />
Shaft seal with cramped graphite-ring in sheet metal<br />
housing<br />
Lubrication of seal is not possible.<br />
Figure 10 � presentation of shaft seal<br />