3.7.7 Electric connection conditions<br />
3.7.7.1 Earthing<br />
BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />
Transport, Installation<br />
Connect the power supply lead according to the<br />
valid regulations of the local electric supply company<br />
and observe in addition:<br />
- the EN DIN VDE-regulations (e.g. Germany),<br />
- the safety regulations,<br />
- the regulations for the prevention of accidents.<br />
As far as the low-voltage line is concerned, use for example<br />
- earthing wire acc. DIN VDE 0255,<br />
- plastic cable acc. DIN VDE 0273,<br />
- cable lugs acc. DIN 46235<br />
- terminal screws<br />
and observe the instructions of the cable and sealing end<br />
manufacturers.<br />
The cross section of the power supply lead depends on the<br />
type of cabling, rated voltage and rated power of the machine.<br />
Cable ends with pressed-on cable lugs must be arranged<br />
and connected in accordance with the connecting plan that is<br />
to be found in the terminal box cover.<br />
The power supply lead and the cable ends must not exert<br />
any lateral and/or torsional power on the terminal studs during<br />
or after the cable connecting work.<br />
In case the fan is provided with electric protection devices<br />
(e.g. position switch), adhere to the instructions of DIN EN<br />
60204-1 Safety of machinery – Electrical equipment of machines.<br />
If the fan and/or its equipment are provided with earthing<br />
clamps, connect the system’s earthing to them.<br />