4.3.2 Check of sense of rotation � Manually check the impeller for unblocked run.<br />

4.3.3 Commutating wrong sense of<br />

rotation<br />

BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />

Start-up<br />

� Switch on the motor and check the sense of rotation for<br />

compliance with the sense of rotation arrow arranged at<br />

the back of the fan.<br />

� Disconnect the fan.<br />

� The following motor connection results from the sense of<br />

rotation:<br />

Connection L1, L2, L3<br />

U1 - V1 - W1 clockwise<br />

Sense of rotation facing<br />

the drive side (motor<br />

shaft journal)<br />

W1 - V1 - U1 counterclockwise<br />

When checking the sense of rotation, only the assigned<br />

inspector is permitted to be present within the<br />

danger area of the fan. Switch on motor and check<br />

sense of rotation (observe valid regulations, e.g. DIN<br />

VDE 0105).<br />

� Ensure that the motor is switched dead.<br />

� Secure against restart and mark with relevant information<br />

sign.<br />

� Check for and guarantee dead condition.<br />

� Connect to earth and short-circuit.<br />

� Cover or secure by barrier adjacent alive parts.<br />

If two of the existing connecting lines are interchanged, the<br />

sense of rotation is altered. In this case the connecting<br />

cables must be arranged inside the terminal box in accordance<br />

with the terminal connecting plan shown above and<br />

the sense of rotation.<br />