7.3.1.1 Lubrication instructions<br />
anti-friction bearings<br />
design with taper<br />
design without taper<br />
Figure 8<br />
7.3.1.2 Lubrication intervals<br />
grease pressed<br />
out here<br />
grease pressed<br />
out here<br />
lubrication intervals for other<br />
temperatures<br />
temperature<br />
bearing housing<br />
75° C<br />
80° C<br />
85° C<br />
90° C<br />
95° C<br />
100° C<br />
factor for lubriation<br />
interval<br />
x 1.00<br />
x 0.85<br />
x 0.70<br />
x 0.55<br />
x 0.45<br />
x 0.35<br />
BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />
Maintenance<br />
The anti-friction bearings are to be lubricated during operation<br />
with the indicated quantity and grease type at the<br />
lubrication nipples M10x1 at the<br />
- non-driven end and<br />
- driven end.<br />
Lubrication intervals, grease quantity and grease type<br />
see plate “Maintenance of the bearings”.<br />
The bearing temperature may increase after re-greasing for<br />
a few hours. After the grease has reached the operating<br />
consistency the values return to normal level.<br />
Used grease must be disposed of in a safe manner<br />
consistent with all applicable regulations and in an<br />
environmentally compatible way.<br />
Figure 8� anti-friction bearings design<br />
Lubrication intervals depend on the conditions to which the<br />
grease is subjected such as bearing friction, speed, bearing<br />
load and temperature.<br />
The indicated lubricating intervals refer to a bearing temperature<br />
of 75°C. For other temperatures the interval must be<br />
corrected in accordance with the table shown on the left.<br />
Lubricants can not be mixed arbitrarily because of their most<br />
varying chemical composition.<br />
If a lubricant is used that differs from the first filling lubricant,<br />
consult the lubricant supplier about its applicability for the given<br />
case.<br />
7.3