10.4 Measures in case of recommissioning<br />

BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />

Carry out the following steps:<br />

Fan shutdown<br />

- Check the bearings and shaft seals for tightness<br />

- Check whether the operating materials like oil or grease<br />

have been filled in properly, re-fill or re-grease if necessary<br />

or exchange the consumables<br />

- Check the V-belts for damage, cracks, ruptures, embrittlement<br />

- Check drives and actuators for condensate water in the<br />

terminal box and housing, if necessary, drain the water<br />

and dry the interior.<br />

- Remove the anti-corrosion coating from all bright parts<br />

which could affect the functioning (e.g. shaft seal, shaft<br />

earthing)<br />

It is not permitted to employ damaged or corroded parts or<br />

such parts that are unfit for operation.<br />

Prior to a new start-up, chapter 4 Start-up must be<br />

observed.<br />