9.1.2 Limiting values vibrations<br />

BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />

Table of limiting values for fans:<br />

Annex<br />

Evaluation Zones<br />

A<br />

New State<br />

B C D<br />

Continuous<br />

Machinery<br />

Class<br />

Motor<br />

Power<br />

in kW<br />

Substructure or<br />

System of<br />

Installation<br />

operation<br />

Permissible<br />

for a shorttimeUnacceptable<br />

eff. Schnelle veff in mm/s<br />

2<br />

> 15<br />

≤ 300<br />

rigid<br />

flexible<br />

≤ 1,4<br />

≤ 2,3<br />

1,4 - 2.8<br />

2,3 - 4,5<br />

2,8 - 4,5<br />

4,5 - 7,1<br />

> 4,5<br />

> 7,1<br />

1 > 300<br />

rigid<br />

flexible<br />

≤ 2,3<br />

≤ 3,5<br />

2,3 - 4,5<br />

3,7 - 7,1<br />

4,5 - 7,1<br />

7,1 - 11<br />

> 7,1<br />

> 11<br />

The values assigned to the rating zones are not intended to<br />

serve as acceptance values. The acceptance values have to<br />

be specified between the machine manufacturer and the<br />

customer. The values should serve as guidelines to avoid<br />

major errors or unrealistic requirements.<br />

The above shown warning and disconnecting values regarding<br />

the working temperature are maximum values. They are<br />

related to an ambient temperature of 40°C and an altitude of<br />

installation of up to 1000 m asl. Under special circumstances<br />

these values can be exceeded, if the preceding agreement<br />

of the manufacturer is obtained.<br />

Evaluation criteria regarding vibrations according to German<br />

standard DIN ISO 10816/3.<br />

If the vibration values level out between warning and disconnecting<br />

and if the fan is carefully observed, the operating of<br />

the fan can be continued until a proper point of time is defined,<br />

so the process can be shut down in a controlled way.<br />

Possible damages of the fan can not be excluded � if required,<br />

inform Konrad Reitz <strong>Ventilatoren</strong> GmbH & Co. KG.<br />