9.1.2 Limiting values vibrations<br />
BWA-<strong>KXE</strong>-Fetteinzelstehlager_englisch_02.doc<br />
Table of limiting values for fans:<br />
Annex<br />
Evaluation Zones<br />
A<br />
New State<br />
B C D<br />
Continuous<br />
Machinery<br />
Class<br />
Motor<br />
Power<br />
in kW<br />
Substructure or<br />
System of<br />
Installation<br />
operation<br />
Permissible<br />
for a shorttimeUnacceptable<br />
eff. Schnelle veff in mm/s<br />
2<br />
> 15<br />
≤ 300<br />
rigid<br />
flexible<br />
≤ 1,4<br />
≤ 2,3<br />
1,4 - 2.8<br />
2,3 - 4,5<br />
2,8 - 4,5<br />
4,5 - 7,1<br />
> 4,5<br />
> 7,1<br />
1 > 300<br />
rigid<br />
flexible<br />
≤ 2,3<br />
≤ 3,5<br />
2,3 - 4,5<br />
3,7 - 7,1<br />
4,5 - 7,1<br />
7,1 - 11<br />
> 7,1<br />
> 11<br />
The values assigned to the rating zones are not intended to<br />
serve as acceptance values. The acceptance values have to<br />
be specified between the machine manufacturer and the<br />
customer. The values should serve as guidelines to avoid<br />
major errors or unrealistic requirements.<br />
The above shown warning and disconnecting values regarding<br />
the working temperature are maximum values. They are<br />
related to an ambient temperature of 40°C and an altitude of<br />
installation of up to 1000 m asl. Under special circumstances<br />
these values can be exceeded, if the preceding agreement<br />
of the manufacturer is obtained.<br />
Evaluation criteria regarding vibrations according to German<br />
standard DIN ISO 10816/3.<br />
If the vibration values level out between warning and disconnecting<br />
and if the fan is carefully observed, the operating of<br />
the fan can be continued until a proper point of time is defined,<br />
so the process can be shut down in a controlled way.<br />
Possible damages of the fan can not be excluded � if required,<br />
inform Konrad Reitz <strong>Ventilatoren</strong> GmbH & Co. KG.<br />
9.2