216 Processing <strong>Modflow</strong><br />

< To define the aquifer type<br />

1. Select Grid < Layer Type …<br />

2. In the Layer Options dialog box, click on Type and select Unconfined, it is ok to browse<br />

through the rest <strong>of</strong> this dialog box, but leave all the values as the default ones.<br />

3. Click OK to leave the Layer Options dialog box.<br />

Flow boundaries<br />

MODFLOW uses an array called the IBOUND array to determine if a particular cell is active,<br />

inactive (no flow) or a fixed-head cell. Cells values within IBOUND are as follows:<br />

active = 1 (or other positive integers)<br />

inactive = 0<br />

fixed-head = -1 (or other negative integers)<br />

These values are assigned to cells as required in the Data Editor. By default and convention<br />

the area outside the model domain is deemed to be a “No Flow Zone” and as such it is not<br />

necessary to set this area to inactive.<br />

< To specify the IBOUND data<br />

1. Select Grid < Boundary Condition < IBOUND (<strong>Modflow</strong>)<br />

2. Ensure the cell selected is [1,1,1] and click the right mouse button to open the Cell Value<br />

dialog box. Since this is going to be a fixed-head boundary enter -1, and click OK to exit<br />

the dialog box. The cell should now have a blue color signifying that it has been set as<br />

fixed-head.<br />

To save doing this for the remaining fixed-head cells it is possible to copy the value (in this<br />

case -1) to any other cell.<br />

3. Click on the Duplication Button , duplication is activated if the relief <strong>of</strong> the button is<br />

sunk.<br />

4. Simply click the left mouse button in any cell that you want to specify as a fixed-head cell.<br />

If you make a mistake, turn <strong>of</strong>f the Duplication Button and click the right mouse button in<br />

the cell where you have entered the wrong value and replace it with the desired value.<br />

5. Complete specifying the entire North boundary and the portion <strong>of</strong> the South boundary west<br />

<strong>of</strong> the mountain as fixed-head cells. We will assign a head value to these cells a little later.<br />

Areas at the model extents are assigned as No Flow by default. However, the mountain area in<br />

the south corner <strong>of</strong> the domain needs to be explicitly assigned as No Flow (ie. IBOUND=0).<br />

6.1.1 Tutorial 1 - Unconfined Aquifer System with Recharge