Processing <strong>Modflow</strong> 21<br />

Table 2.4 Output from the Water Budget Calculator for the pumping well<br />

FLOWS ARE CONSIDERED "IN" IF THEY ARE ENTERING A SUBREGION<br />

THE UNIT OF THE FLOWS IS [L^3/T]<br />

TIME STEP 1 OF STRESS PERIOD 1<br />

ZONE= 1 LAYER= 1<br />

FLOW TERM IN OUT IN-OUT<br />

STORAGE 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

CONSTANT HEAD 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

HORIZ. EXCHANGE 7.7992809E-05 0.0000000E+00 7.7992809E-05<br />

EXCHANGE (UPPER) 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

EXCHANGE (LOWER) 0.0000000E+00 7.9696278E-05 -7.9696278E-05<br />

WELLS 0.0000000E+00 1.0000000E-10 -1.0000000E-10<br />

DRAINS 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

RECHARGE 3.1999998E-06 0.0000000E+00 3.1999998E-06<br />

. . . .<br />

. . . .<br />

SUM OF THE LAYER 8.1192811E-05 7.9696380E-05 1.4964317E-06<br />

. . . .<br />

. . . .<br />

ZONE= 2 LAYER= 2<br />

FLOW TERM IN OUT IN-OUT<br />

STORAGE 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

CONSTANT HEAD 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

HORIZ. EXCHANGE 5.6035380E-04 0.0000000E+00 5.6035380E-04<br />

EXCHANGE (UPPER) 7.9696278E-05 0.0000000E+00 7.9696278E-05<br />

EXCHANGE (LOWER) 0.0000000E+00 6.4027577E-04 -6.4027577E-04<br />

WELLS 0.0000000E+00 1.0000000E-10 -1.0000000E-10<br />

. . . .<br />

. . . .<br />

SUM OF THE LAYER 6.4005010E-04 6.4027589E-04 -2.2578752E-07<br />

ZONE= 3 LAYER= 3<br />

FLOW TERM IN OUT IN-OUT<br />

STORAGE 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

CONSTANT HEAD 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

HORIZ. EXCHANGE 5.5766129E-04 0.0000000E+00 5.5766129E-04<br />

EXCHANGE (UPPER) 6.4027577E-04 0.0000000E+00 6.4027577E-04<br />

EXCHANGE (LOWER) 0.0000000E+00 0.0000000E+00 0.0000000E+00<br />

WELLS 0.0000000E+00 1.2000001E-03 -1.2000001E-03<br />

. . . .<br />

. . . .<br />

SUM OF THE LAYER 1.1979371E-03 1.2000001E-03 -2.0629959E-06<br />

Step 6: Produce Output<br />

In addition to the water budget, PMWIN provides various possibilities for checking simulation<br />

results and creating graphical outputs. Pathlines and velocity vectors can be displayed by<br />

PMPATH. Using the Results Extractor, simulation results <strong>of</strong> any layer and time step can be<br />

read from the unformatted (binary) result files and saved in ASCII Matrix files. An ASCII<br />

Matrix file contains a value for each model cell in a layer. PMWIN can load ASCII matrix files<br />

into a model grid. The format <strong>of</strong> the ASCII Matrix file is described in Appendix 2. In the<br />

following, we will carry out the steps:<br />

1. Use the Results Extractor to read and save the calculated hydraulic heads.<br />

2. Generate a contour map based on the calculated hydraulic heads for the first layer.<br />

3. Use PMPATH to compute pathlines as well as the capture zone <strong>of</strong> the pumping well.<br />

2.1 Run a Steady-State Flow Simulation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!