The information transferred via <strong>DR</strong>IVE-CLiQ is defined in the PROFIdrive profile (available<br />

through the Profibus user organization.)<br />

Displayed position values:<br />

XIST1: Incremental value (X actl.)<br />

XIST2: Absolute value (X actl.)<br />

Position value 2: Redundant position value of encoders that support 'Functional safety', or<br />

incremental position value for conversion EnDat 2.2 --> <strong>DR</strong>IVE-CLiQ<br />

Status information<br />

Error: Error message from connected encoder<br />

Transmission: Error in data transmission, e.g. CRC, packet loss, ...<br />

Pos. dev.: Position comparison of XIST1 with Pos2 of encoders supporting 'Functional safety'<br />

Commu. or Speed: The ATS software compares the values for the commutation angle or<br />

speed transferred from the encoder on the basis on XIST1.<br />

Auxiliary information screen:<br />

Commutation or Speed:<br />

Encoders with a <strong>DR</strong>IVE-CLiQ interface compute these values in the encoder and then transfer<br />

them to the interface.<br />

Temperature sensor external:<br />

Display of the temparture of an external temperature sensor, if supported by the encoder.<br />

(An extremely low or high value indicates that no temperature sensor is connected.)<br />

108 <strong>HEIDENHAIN</strong> ATS Software Operating Instructions