2. Editing in the datum shift window:<br />

Clicking the button right from "Datum shift value" opens the "Datum shift"<br />

window.<br />

Here the value (decimal/hexadecimal/binary) can be edited; click OK to confirm.<br />

Note<br />

Entering the value 0 cancels the datum shift.<br />

Attention<br />

If the datum shift is edited in the operating parameters area, the ATS software does not<br />

check, whether the entry value is EnDat-compatible.<br />

Click the "EnDat" button ("Save encoder configuration in encoder") to open the<br />

window for selecting the memory area.<br />

Select the "Operating parameters" memory area.<br />

Click the "Transfer" button to save the data in the encoder.<br />