Closed Loop<br />
The control loop of the machine axis is closed, a T-coupler/signal splitter (Service Adapter<br />
SA 1x0) is connected between the encoder and the subsequent electronics.<br />
The PWM 20 or the IK 215 are connected to the diagnostic output which is metallically isolated.<br />
Now, the ATS software can monitor the data stream between subsequent electronics and<br />
encoder.<br />
Note<br />
The ATS software cannot request data actively; it can only passively monitor data<br />
communication between subsequent electronics and encoder. The closed-loop functionality<br />
only works for interfaces at which the subsequent electronics permanently requests<br />
diagnostic data. (The diagnostic function of the subsequent electronics must be active!)<br />
Otherwise, no data communication can be monitored (possible with EnDat 02, 21 und 22,<br />
Fanuc, Mitsubishi)!<br />
Flow chart for interrogation of diagnostics data:<br />
March 2011 Software Description 77