Status display Each time position data are transferred, status information is included and evaluated.<br />

Depending on the encoder model, information on encoder alarms and warnings and on the<br />

quality of the incremental signal are available.<br />

EnDat 2.1<br />

status display<br />

1 In shortened form (group signal) the encoder status is displayed in the lower area of the<br />

position display screen as a colored LED symbol.<br />

2 Use the magnifying glass symbol to display detailed information.<br />

The EnDat interface allows for extensive monitoring of the encoder. Ein An alarm becomes<br />

active if there is a malfunction in the encoder that is presumably causing incorrect position<br />

values.<br />

Some examples of alarms:<br />

Failure of the light unit<br />

Signal amplitude too low<br />

Incorrect position value<br />

Supply voltage too high / too small<br />

Excessive current consumption<br />

Warnings indicate that certain tolerances of the encoder were reached or exceeded (e.g. speed,<br />

control reserve of the light unit) but the position value is not incorrect. If a warning is displayed<br />

the encoder concerned should be inspected or exchanged as soon as possible in order to avoid<br />

down times.<br />