- compressor start sequence and automatic lead/lag selection<br />
- alarm signalling<br />
- alarm reset<br />
- capacity steps<br />
- common alarm contact for remote signalling<br />
- automatic capacity step reduction when high pressure limit is reached<br />
- recording of historical alarm data<br />
LCD display of the following information:<br />
- water outlet temperature<br />
- programmed temperature set-point and differential<br />
- alarm descriptions<br />
- compressor hours run meter, number of unit and compressor starts and pumps (if installed)<br />
- high and low pressure values and relative condensation and evaporation temperature values.<br />
- discharge gas temperature<br />
Electric power supply [V/f/Hz]: 400/3~/50 ±5%<br />
CONTROLS AND SAFETY DEVICES<br />
- double safety high pressure switch with manual reset<br />
- High pressure safety, with automatic reset, controlled by the unit controller<br />
- Low pressure safety switch, with automatic reset, controlled by the unit controller<br />
- High pressure relief valve<br />
- freeze protection probe at the outlet of each evaporator<br />
- chilled water temperature probe (located at evaporator inlet)<br />
- mechanical flow switch<br />
- compressor and fan over-temperature protection<br />
- Compressor cooling device with liquid injection.<br />
TESTING<br />
Units are subjected to a factory test and supplied complete with oil and refrigerant.<br />
<strong>KAPPA</strong> V <strong>ECHOS</strong> UNIT VERSIONS<br />
<strong>KAPPA</strong> V <strong>ECHOS</strong> /HP: reverse cycle heat pump<br />
In addition to the components of version <strong>KAPPA</strong> V <strong>ECHOS</strong>, this unit includes:<br />
Refrigerant circuit: 4-way reversing valve, suction separator, liquid receiver, second thermostatic expansion valve.<br />
Microprocessor enabled for summer/winter changeover and automatic defrost independently controlled for each<br />
compressor, with a patented Blue Box logic, to obtain the maximum efficiency in the intervention and duration of<br />
defrost cycles.<br />
HYDRAULIC MODULE OPTIONS<strong>KAPPA</strong> V <strong>ECHOS</strong> 2PS: unit with storage tank and pumps.<br />
In addition to the components of version <strong>KAPPA</strong> V <strong>ECHOS</strong> this unit includes:<br />
insulated storage tank; run and standby circulating pumps, with automatic changeover by time or fault.<br />
Expansion tank, check valves and gate valves.<br />
Version ST is available in the following additional three configurations:<br />
- ST 1PS: with 1 pump and a tank;<br />
- ST 1P: with 1 pump without a tank.<br />
- ST 2P: with 2 pumps without a tank<br />
<strong>AC</strong>CESSORY VERSIONS<br />
<strong>KAPPA</strong> V <strong>ECHOS</strong> /DC: unit with heat recovery condenser<br />
In addition to the components of version <strong>KAPPA</strong> V <strong>ECHOS</strong> this unit includes, in each refrigerant circuit, a 100%<br />
heat recovery brazed plate type condenser for the production of hot water and a liquid receiver. The recovery<br />
condenser is a brazed plate type for models 16.1 and 32.2 and shell and tube for the remainder of the range.<br />
The microprocessor automatically controls the water temperature and the high-pressure heat recovery safety<br />
switch.<br />
For the maximum efficiency of the device it is advisable to couple with fan speed control. Not available on HP<br />
version.<br />