Wieg<strong>and</strong> Serial Module Configuration—Read/Write<br />

(Does not apply to SNAP Simple I/O) Use this area to configure SNAP Wieg<strong>and</strong> serial<br />

communication modules on the rack. Only a few modules <strong>and</strong> ports are shown in the table. Other<br />

ports <strong>and</strong> modules on the rack follow the same pattern. See the table on page 114 for a list of<br />

module <strong>and</strong> port numbers.<br />

For important information on using these modules, see Opto 22 form 1191, SNAP Serial<br />

Communication Module User’s Guide.<br />

Starting Address Length Type Description<br />

FFFF F03A 8500 4 UI Wieg<strong>and</strong> module 0: Loader version number<br />

FFFF F03A 8504 4 UI Wieg<strong>and</strong> module 0: Firmware (kernel) version number<br />

FFFF F03A 8508 4 UI Wieg<strong>and</strong> module 1: Loader version number<br />

FFFF F03A 850C 4 UI Wieg<strong>and</strong> module 1: Firmware (kernel) version number<br />

(Modules 2–15 follow in order.)<br />

FFFF F03A 8600 4 UI Port A on Wieg<strong>and</strong> module in position 0 on the rack: IP port number<br />

for access to serial port. Default is 22500.<br />

FFFF F03A 8604 4 UI Port A, position 0: Data format (O for Opto format, 26, 30, 32, 34,<br />

35, 36, 37, 40, or C for custom format)<br />

FFFF F03A 8608 4 UI Port A, position 0: Total length of data in the transmission<br />

FFFF F03A 860C 4 UI Port A, position 0: First bit of the site code<br />

FFFF F03A 8610 4 UI Port A, position 0: Length of the site code, in bits<br />

FFFF F03A 8614 4 UI Port A, position 0: First bit of the badge code (should be the next bit<br />

after the site code)<br />

FFFF F03A 8618 4 UI Port A, position 0: Length of the badge code, in bits<br />

FFFF F03A 861C 24 -- Pad for alignment<br />

FFFF F03A 8640 4 UI Port B on Wieg<strong>and</strong> module in position 0 on the rack: IP port number<br />

for access to serial port. Default is 22501.<br />

FFFF F03A 8644 4 UI Port B, position 0: Data format (O for Opto format, 26, 30, 32, 34,<br />

35, 36, 37, 40, or C for custom format)<br />

FFFF F03A 8648 4 UI Port B, position 0: Total length of data in the transmission<br />

FFFF F03A 864C 4 UI Port B, position 0: First bit of the site code<br />

FFFF F03A 8650 4 UI Port B, position 0: Length of the site code, in bits<br />

FFFF F03A 8654 4 UI Port B, position 0: First bit of the badge code (should be the next bit<br />

after the site code)<br />

FFFF F03A 8658 4 UI Port B, position 0: Length of the badge code, in bits<br />

SNAP Ethernet-Based I/O Units Protocols <strong>and</strong> Programming Guide 113