appendix 1 - Victor Technologies
appendix 1 - Victor Technologies
appendix 1 - Victor Technologies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
NOTE<br />
Art may differ<br />
from actual unit.<br />
7. Reinstall the Side Panel as follows:<br />
A-03045<br />
a. Reconnect the ground wire to the Side Panel, if disconnected.<br />
b. Place the Side Panel onto the frame and slide the top<br />
edge under the lip on the Top Panel.<br />
c. Reinstall all the screws to secure the Side Panel.<br />
C. Diode Testing Basics<br />
Testing of diode modules requires a digital volt/ohmmeter that<br />
has a diode test scale. Remember that even if the diode module<br />
checks good, it may still be bad. If in doubt, replace the diode<br />
module.<br />
1. Locate the diode module to be tested.<br />
2. Remove cables from mounting studs on diodes to isolate<br />
the module.<br />
3. Set digital volt/ohmmeter to diode test scale.<br />
4. Using the Figures for each test, check each diode in the<br />
module. Each diode must be checked in forward bias (plus<br />
to negative) and reverse bias (negative to plus) direction.<br />
5. Connect the volt/ohmmeter positive lead to the anode (+)<br />
of the diode and the negative lead to the cathode (-) of the<br />
diode for forward bias testing (refer to following figure). A<br />
properly functioning diode will conduct in the forward bias<br />
direction and indicate between 0.3 to 0.9 volts.<br />
Anode<br />
Cathode<br />
Forward Bias<br />
Diode Conducting<br />
Diode Test Symbol<br />
Art # A-00307<br />
Manual 0-2697 4-13 SERVICE<br />
0.75<br />
VR COM A<br />
+ _<br />
Testing Diode Forward Bias<br />
6. Reverse the meter leads across the diode for reverse bias<br />
testing (refer to following figure). A properly functioning<br />
diode will block in the reverse bias direction and depending<br />
on the meter function will indicate an open or “OL”.<br />
Reverse Bias<br />
Diode Not Conducting<br />
Cathode<br />
Anode<br />
Art # A-00306<br />
OL<br />
VR COM A<br />
+ _<br />
Testing Diode Reverse Bias<br />
7. If a diode checks bad, replace the diode module.<br />
8. Reconnect all cables to proper terminals.