appendix 1 - Victor Technologies
appendix 1 - Victor Technologies
appendix 1 - Victor Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
J99<br />
D36<br />
8<br />
1<br />
Logic PC Board<br />
Logic PC Board Signals<br />
APPENDIX 4: LOGIC PC BOARD LAYOUT<br />
J17<br />
1 12 1<br />
D31<br />
J96<br />
J1-1 36 VAC from Auxiliary Transformer<br />
J1-2 115 VAC from Auxiliary Transformer<br />
J1-3 Center Tap from Auxiliary Transformer<br />
J1-4 Not Used<br />
J1-5 36 VAC from Auxiliary Transformer<br />
J1-6 115 VAC Return from Auxiliary Transformer<br />
J2-1 115 VAC Return to Main Contactor<br />
J2-2 115 VAC Return to Plasma Solenoid<br />
J2-3 Not Used<br />
J2-4 115 VAC to Main Contactor<br />
J2-5 Not Used<br />
J2-6 115 VAC to Secondary Solenoid<br />
J2-7 Not Used<br />
J2-8 Not Used<br />
J2-9 Pressure Switch +12 vdc Signal<br />
J2-10 Pressure Switch Return<br />
4<br />
24<br />
1<br />
D65<br />
J5<br />
TP1 (Ground)<br />
D26 D25<br />
J2-11 Over Temp Sw. (Input Bridge, Pilot Bd, Radiator) 12V<br />
J2-12 Over Temp Sw. (Input Bridge, Pilot Bd, Radiator) Return<br />
J2-13 Not Used<br />
J2-14 Not Used<br />
J2-15 Not Used<br />
J2-16 Not Used<br />
J3-1 36 VAC to ON/OFF Switch<br />
J3-2 36 VAC from ON/OFF Switch<br />
J3-3 36 VAC to ON/OFF Switch<br />
J3-4 36 VAC from ON/OFF Switch<br />
J3-5 RUN/SET Switch on Front Panel +12V signal<br />
J3-6 RUN/SET Switch on Front Panel Return<br />
J3-7 Main Current Control Signal (High) +10 vdc<br />
J3-8 Main Current Control Pot (Wiper)<br />
J3-9 Main Current Control Pot (Low)<br />
APPENDIX A-4 Manual 0-2697<br />
J2<br />
12<br />
2 1 5<br />
J1<br />
1<br />
1<br />
18<br />
J3<br />
D47<br />
1<br />
2<br />
A-02310<br />
J4 J4<br />
20<br />
19