APPENDIX 2: SEQUENCE OF OPERATION (BLOCK<br />

DIAGRAM)<br />

ACTION<br />

Close external<br />

disconnect switch.<br />

RESULT<br />

Power to system.<br />

ACTION<br />

Protect eyes and<br />

activate torch<br />

RESULT<br />

Gas flows (2 seconds).<br />

After gas pre-flow:<br />

DC indicator on.<br />

Pilot arc established<br />

ACTION<br />

Torch deactivated (by torch switch<br />

release or by remote device).<br />

RESULT<br />

Main arc stops.<br />

(Power supply enable signal removed.)<br />

Gas flows (15 seconds)<br />

NOTE - If torch is activated during<br />

post-flow, pilot arc will immediately restart.<br />

If torch is within transfer distance (3/8 in) of<br />

workpiece, main arc will transfer.<br />

After post-flow:<br />

Gas solenoid closes, gas flow stops.<br />

GAS indicator off.<br />

A-03050<br />

ACTION<br />

ON/OFF switch<br />

to ON.<br />

RESULT<br />

AC indicator blinks for 8<br />

seconds then steady on.<br />

Fans on.<br />

Power circuit ready.<br />

PILOT ARC<br />

ACTION<br />

RUN/SET switch<br />

to SET.<br />

RESULT<br />

Gas solenoid open,<br />

gas flows to set pressure.<br />

GAS indicator on.<br />

ACTION<br />

ON/OFF switch<br />

to OFF<br />

RESULT<br />

All indicators off.<br />

Power supply fans off.<br />

ACTION<br />

STANDARD/LATCH<br />

switch to STANDARD<br />

ACTION<br />

STANDARD/LATCH<br />

switch to LATCH<br />

ACTION<br />

Torch moved away<br />

from work (while<br />

still activated).<br />

RESULT<br />

Main arc stops.<br />

Pilot arc automatically<br />

restarts.<br />

ACTION<br />

RUN/SET switch<br />

to RUN.<br />

RESULT<br />

Gas flow stops.<br />

GAS indicator off.<br />

ACTION<br />

Torch moved within<br />

transfer distance of workpiece.<br />

RESULT<br />

Main arc transfer.<br />

Pilot arc off.<br />

ACTION<br />

Torch Switch released.<br />

RESULT<br />

Transfer will continue<br />

until torch is removed<br />

from workpiece.<br />

ACTION<br />

Open external<br />

disconnect.<br />

RESULT<br />

No power to system.<br />

APPENDIX A-2 Manual 0-2697