System Startup<br />

Troubleshooting Tip: if the JCU does not have power, it may be connected<br />

to a Power over Ethernet (PoE) switch which has not been powered on, or it<br />

may be connected to a network switch that does not provide PoE power.<br />

Bootup Mode<br />

The following section describes what happens when the circuit breaker is<br />

energized and power is applied to the camera. The camera will stay in the<br />

Bootup state for approximately 55 seconds. During the bootup process,<br />

the bootup screen and messages are displayed on the monitor, followed by<br />

live video, which is displayed only momentarily, until the camera goes into<br />

standyby mode..<br />

Initially the FLIR splash screen will appear, as shown to the left. Then<br />

another splash screen with two important notices will appear:<br />

Warning: Do not use the M-Series imaging system as the primary navigation<br />

system. Use it in conjunction with a primary navigation system and<br />

other navigation aids.<br />

Note: The M-Series IR Thermal Imaging System is an Export Controlled<br />

item. Authorization by the U.S. Government must be obtained prior to<br />

export outside the United States.<br />

After the splash screens are displayed, the video screen will show a message<br />

that says “Loading, please wait...” 1 When the bootup is complete,<br />

the monitor will briefly show live video, and then the display will be<br />

blank, to indicate the camera is in Standby mode. The gimbal assembly<br />

20 432-0003-00-10 rev 140 M-Series Operator’s Manual