Troubleshooting Tips<br />
On Screen Messages<br />
In some circumstances, a status or alert message may appear on the video<br />
screen. This section describes the messages and the appropriate actions<br />
that may be necessary.<br />
"Loading, please wait…"<br />
Indicates the camera has power and is booting up. No action is needed; the<br />
message will be removed when camera is ready for operation.Refer to<br />
Chapter 2 System Startup for more information.<br />
"Reconnect network, now..."<br />
Indicates the camera has detected a loopback termination on the Ethernet<br />
RJ45 connector and has reverted to the Factory Default network settings2 .<br />
Remove the Ethernet RJ45 loopback termination adapter. The camera will<br />
then continue the start-up process under the Factory Default network configuration<br />
(with DHCP dynamic IP addressing).<br />
"Warming, please wait…<br />
Indicates the camera has detected a low temperature condition and does<br />
not allow pan/tilt motion until it is sufficiently warm. Wait for the camera to<br />
self-heat to an operational temperature (the amount of time will vary<br />
depending on the outside temperature). The message will be removed when<br />
camera is ready to operate.<br />
"High Temperature - Motor Halted"<br />
Indicates the camera has detected an over-temperature condition and has<br />
disabled the internal pan/tilt motor power. Confirm the temperature of the<br />
camera is within the allowed operational temperature range. Allow the camera<br />
to cool down to a temperature within the operating range.<br />
"High Temp. - Shutdown System #"<br />
Indicates the camera has detected an over-temperature condition and must<br />
be shutdown. The '#' character displays a 5 second countdown. The user<br />
should onfirm the temperature of the camera is within the allowed operational<br />
temperature range. Turn off the power to the camera and allow it to<br />
cool down to a temperature within the operating range. If the problem continues,<br />
contact FLIR.<br />
2 Refer to the following section for more information about the RJ45 loopback connector<br />
and how to restore the network settings to factory defaults.<br />