You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Settings menu (SEt)<br />
52<br />
Code Name/Description R/W Adjustment range Factory setting<br />
SEt Settings menu (continued)<br />
ACC • Acceleration time R/W 1..60 s 10 s<br />
Determines motor’s voltage ramp up time, if SSC is set to OFF.<br />
Determines motor’s torque ramp up time, if SSC is set to ON.<br />
Run command<br />
dEC • Deceleration time R/W FrEE, 1...60 s Free<br />
1 to 60<br />
FrEE<br />
Determines motor’s voltage ramp down time, if SSC is set to OFF.<br />
Determines motor’s torque ramp down time, if SSC is set to ON.<br />
- Deceleration time<br />
- Freewheel deceleration<br />
%<br />
Run<br />
EdC • End of deceleration<br />
Time(s)<br />
R/W 0..10 0<br />
Threshold for changing to freewheel stop mode at the end of deceleration.<br />
Soft deceleration will end when the estimated torque falls below the EdC value.<br />
Note: Edc is inactive when dLtA = dLt. In this case, EdC value is not used and is not relevant.<br />
Motor<br />
voltage<br />
tHP • Motor thermal protection<br />
10<br />
20<br />
30<br />
dEC<br />
Freewheel<br />
Time(s)<br />
Motor<br />
voltage<br />
R/W 10<br />
To select the class of motor thermal protection, see explanations and curves page 22.<br />
- IEC class 10<br />
- IEC class 20<br />
- IEC class 30 (heavy duty)<br />
Note: To activate the Motor thermal protection, set ItH to ErUn or On, page 59<br />
Freewheel