Parameter Index and Modbus addresses<br />

Code Page Name Unit<br />

LI* Logical inputs<br />

LI2 60 Logic input 2 -<br />

LI3 60 Logic input 3 -<br />

Lo 47<br />

OIt 57<br />

OId 56<br />

OSd 59<br />

OSt 58<br />

Logic Output relays<br />

status<br />

Overcurrent time<br />

delay<br />

Overcurrent<br />

threshold<br />

Over voltage<br />

threshold<br />

Under voltage time<br />

delay<br />

(1) Modbus code = Soft starter message<br />

example : oFF on the soft starter will be equivalent to "0" with Modbus protocol (remote command)<br />

* : parameter visible only with Modbus<br />

Modbus<br />

code and<br />

Adjustment<br />

Range (1)<br />

d0: Input 1. 0 – open, 1 – closed.<br />

d1: Input 2.<br />

d2: Input 3.<br />

d3...d15: Reserved<br />

0 = Strt<br />

1 = rUn<br />

2 = 2nd<br />

3 = EtF<br />

4 = rSt<br />

5 = FAn<br />

6 = FI<br />

7 = LIL<br />

2 = 2nd<br />

3 = EtF<br />

4 = rSt<br />

5 = FAn<br />

6 = FI<br />

7 = LIL<br />

Description<br />

start:for a 3-wire control<br />

run:for a 2-wire control<br />

2nd set of parameters<br />

external detected fault<br />

remote reset<br />

fan control<br />

trip inhibition<br />

forced local command<br />

2nd set of parameters<br />

external detected fault<br />

remote reset<br />

fan control<br />

trip inhibition<br />

forced local command<br />

d0: Relay 1. 0 – not energized, 1 - energized<br />

d1: Relay 2<br />

d2...d15: reserved<br />

s 0 to 50 s<br />

%<br />

ofIn<br />

%<br />

of Uln<br />

100 to 300, by<br />

increment of 5<br />

PG* Proportional gain % 0 to 100%<br />

PHL 58<br />

Phase loss<br />

detection<br />

PHr 57 Phase sequence -<br />

PtC 59<br />

PTC probes motor<br />

monitoring<br />

5 with Modbus = 0.5s<br />

50 with Modbus = 5.0s<br />

Modbus<br />

address<br />

261<br />

Factory<br />

setting<br />

72 rUn<br />

73 rSt<br />

262<br />

51 0.5<br />

- 50 200<br />

110 to 125 - 60 120<br />

s 1 to 10 - 61 2<br />

-<br />

-<br />

0 = oFF<br />

1 = On<br />

0 = 123<br />

1 = 321<br />

2 = oFF<br />

0 = oFF<br />

1 = On<br />

This parameter is reserved<br />

for expert mode.<br />

Active when SSC = On<br />

off<br />

on<br />

123<br />

321<br />

off<br />

off<br />

on<br />

37 60<br />

57 On<br />

56 oFF<br />

62 oFF<br />

User<br />

setting<br />

79