Configuration 61/119<br />
4.4.4 STEP7 Data Types<br />
4.4.4.1 Support of the Process Data Editor<br />
In the process data-editor (Symbol Configuration dialog) data can be read<br />
from or written to the data blocks DB and from/to the symbol area of the<br />
PLC. The symbol area includes the areas:<br />
• Merker (M, MB, MW, MD)<br />
• Counter (C)<br />
• Timer (T)<br />
• Input Area (I)<br />
• Output Area (O)<br />
Data<br />
type<br />
BOOL<br />
Description<br />
Simple STEP7 Data Types and Conversions<br />
Data type for Boolean values. Data are each<br />
stored within a single bit. The range of possible<br />
values only contains the values TRUE and<br />
FALSE.<br />
Range of values Range of values PDI<br />
Lower limit Upper limit<br />
Data Type<br />
FALSE TRUE Bit<br />
BYTE Unsigned 8 bit integer data type 0 255 Byte<br />
WORD Unsigned 16 bit integer data type 0 65535 Word<br />
INT Signed 16 bit integer data type -32768 32767 Signed16<br />
DWORD Unsigned 32 bit integer data type 0 2 32 -1 DWord<br />
DINT Signed 32 bit integer data type -2 31 2 31 -1 Signed32<br />
REAL Signed 32 bit floating point data type with +/-<br />
+/-<br />
Real32<br />
exponential representation<br />
1.175495e-38 3.402823e+38<br />
CHAR 8 bit character data type for storing single<br />
ASCII characters. Internal processing as being<br />
of type BYTE.<br />
All ASCII characters allowed<br />
Byte<br />
S5TIME<br />
DATE<br />
TIME<br />
TIME_OF<br />
_DAY<br />
Unsigned 16 bit data type for storage of the<br />
S7 ® –internal time in steps of 10 milliseconds.<br />
Internal processing as being of type WORD.<br />
Unsigned 16 bit data type for storage of the<br />
IEC-time in steps of 1 day. Internal processing<br />
as being of type WORD.<br />
Signed 32 bit data type for storage of the IECtime<br />
in steps of 1 millisecond. Internal<br />
processing as being of type DWORD.<br />
32 bit data type for storage of the clock time in<br />
steps of 1 millisecond. Internal processing as<br />
being of type DWORD.<br />
Valid time<br />
specification<br />
0H_0M_0S_0MS<br />
Valid date<br />
2H_46M_30S_<br />
0MS<br />
1990-1-1 2168-12-31<br />
Valid time<br />
specification<br />
-24D_20H_31M_<br />
23S_648MS<br />
Valid time of day<br />
Table 20: Simple STEP7 Data Types / Conversions<br />
24D_20H_<br />
31M_23S_<br />
647MS<br />
0:0:0.0 23:59:59.999<br />
Word<br />
Word<br />
DWord<br />
DWord<br />
<strong>DTM</strong> for Hilscher <strong>PROFIBUS</strong> <strong>MPI</strong> Devices | Configuration of Hilscher <strong>MPI</strong> Devices<br />
DOC0110402OI01EN | Revision 01 | English | 2011-07 | In Development | Public © Hilscher, 2007-2011