Configuration 61/119<br />

4.4.4 STEP7 Data Types<br />

4.4.4.1 Support of the Process Data Editor<br />

In the process data-editor (Symbol Configuration dialog) data can be read<br />

from or written to the data blocks DB and from/to the symbol area of the<br />

PLC. The symbol area includes the areas:<br />

• Merker (M, MB, MW, MD)<br />

• Counter (C)<br />

• Timer (T)<br />

• Input Area (I)<br />

• Output Area (O)<br />

Data<br />

type<br />

BOOL<br />

Description<br />

Simple STEP7 Data Types and Conversions<br />

Data type for Boolean values. Data are each<br />

stored within a single bit. The range of possible<br />

values only contains the values TRUE and<br />

FALSE.<br />

Range of values Range of values PDI<br />

Lower limit Upper limit<br />

Data Type<br />

FALSE TRUE Bit<br />

BYTE Unsigned 8 bit integer data type 0 255 Byte<br />

WORD Unsigned 16 bit integer data type 0 65535 Word<br />

INT Signed 16 bit integer data type -32768 32767 Signed16<br />

DWORD Unsigned 32 bit integer data type 0 2 32 -1 DWord<br />

DINT Signed 32 bit integer data type -2 31 2 31 -1 Signed32<br />

REAL Signed 32 bit floating point data type with +/-<br />

+/-<br />

Real32<br />

exponential representation<br />

1.175495e-38 3.402823e+38<br />

CHAR 8 bit character data type for storing single<br />

ASCII characters. Internal processing as being<br />

of type BYTE.<br />

All ASCII characters allowed<br />

Byte<br />

S5TIME<br />

DATE<br />

TIME<br />

TIME_OF<br />

_DAY<br />

Unsigned 16 bit data type for storage of the<br />

S7 ® –internal time in steps of 10 milliseconds.<br />

Internal processing as being of type WORD.<br />

Unsigned 16 bit data type for storage of the<br />

IEC-time in steps of 1 day. Internal processing<br />

as being of type WORD.<br />

Signed 32 bit data type for storage of the IECtime<br />

in steps of 1 millisecond. Internal<br />

processing as being of type DWORD.<br />

32 bit data type for storage of the clock time in<br />

steps of 1 millisecond. Internal processing as<br />

being of type DWORD.<br />

Valid time<br />

specification<br />

0H_0M_0S_0MS<br />

Valid date<br />

2H_46M_30S_<br />

0MS<br />

1990-1-1 2168-12-31<br />

Valid time<br />

specification<br />

-24D_20H_31M_<br />

23S_648MS<br />

Valid time of day<br />

Table 20: Simple STEP7 Data Types / Conversions<br />

24D_20H_<br />

31M_23S_<br />

647MS<br />

0:0:0.0 23:59:59.999<br />

Word<br />

Word<br />

DWord<br />

DWord<br />

<strong>DTM</strong> for Hilscher <strong>PROFIBUS</strong> <strong>MPI</strong> Devices | Configuration of Hilscher <strong>MPI</strong> Devices<br />

DOC0110402OI01EN | Revision 01 | English | 2011-07 | In Development | Public © Hilscher, 2007-2011