BIB Over-current Protective Device (1)<br />

• Fuses are commonly used to isolate and protect the UUT on BIB.<br />

• Us<strong>in</strong>g correct fuse current rat<strong>in</strong>g, type (fast or slow-act<strong>in</strong>g) and derat<strong>in</strong>g<br />

factor is important to avoid circuit electrical over-stress.<br />

Fuse rat<strong>in</strong>g = Normal Operat<strong>in</strong>g Current/0.75 x % rat<strong>in</strong>g<br />

<strong>Burn</strong>t Trace<br />

Operat<strong>in</strong>g Temp vs Fuse Rat<strong>in</strong>g<br />

% Rat<strong>in</strong>g<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

Slow-Act<strong>in</strong>g<br />

Fast-Act<strong>in</strong>g<br />

PPTC<br />

Lack of protection causes die EOS<br />

-60C<br />

-40C<br />

-20C<br />

0C<br />

20C<br />

25C<br />

40C<br />

60C<br />

Operat<strong>in</strong>g Temp<br />

80C<br />

100C<br />

120C<br />

Fuse value is derated with elevated operat<strong>in</strong>g temperature<br />

• They are current sensitive devices serv<strong>in</strong>g as a weak l<strong>in</strong>k <strong>in</strong> BIB circuit.<br />

• Fuse characteristic is determ<strong>in</strong>ed by respond to various current overload.<br />

• Slow-act<strong>in</strong>g fuse has more thermal <strong>in</strong>ertia that tolerates <strong>in</strong>itial overload<br />

current.<br />

• Fast-act<strong>in</strong>g or very fast-act<strong>in</strong>g fuse is good for sensitive, critical circuits.<br />

KWLow/Zamel <strong>BiTS</strong> 2002 7