DISCUSSION<br />

• Gold coated conductor pads particularly those with 50 µ<strong>in</strong> gold<br />

had 0 opens and the conductor pads had best appearance.<br />

• Initial resistance and resistance <strong>in</strong>crease with burn-<strong>in</strong> time was<br />

smallest with gold coated conductor pads compared with pads<br />

coated with nickel, solder and bare copper conductor pads.<br />

• Conductor pad coat<strong>in</strong>gs of nickel and solder had larger<br />

<strong>in</strong>creases <strong>in</strong> resistance. Bare copper conductor pads had<br />

largest resistance <strong>in</strong>crease with burn-<strong>in</strong> time<br />