CHAPTER 6 COMMUNICATION FUNCTION<br />
3) Parameter setting and modification<br />
If you double click the relevant parameter in the parameter setting basic screen of the<br />
Figure, the high speed link parameter setting screen will appear.<br />
parameter setting initial screen<br />
● Area : to set the reading area of the data to send when sending, and the saving area of<br />
the received data when receiving.<br />
● Size : the size of data for sending/receiving. The unit is 1byte and it is available to set<br />
Point<br />
1kbyte for total sending/receiving G3/4/6L-PUEA and 7kbytes for G3/4/6L-PUEB.<br />
1) The size of sending area and receiving area is total no. of I/O contact that created<br />
in SyCon.<br />
2) G4L-PUEA 1EA, GPL-TR2A(16points), GPL-TR4A(32points), GPL-<br />
D22A(16points) in order and when setting the sending area by<br />
P000, receiving area by P010,<br />
* Sending area : P000<br />
* Receiving area : P010<br />
* Sending area size : 6 bytes(total output contact number)<br />
* Receiving area size : 2 bytes(total input contact number),<br />
* P000의 data -> output by GPL-TR2A<br />
* P001~P002 data -> output by GPL-TR4A<br />
* GPL-D22A input -> saved in P010.<br />
3) The created order in SyCon is prior to station no. and cable connection when<br />
sending/receiving the data.<br />
6-24