Power Engineering<br />

Class I (T1) Lightning Current Arresters<br />

PowerPro B TN-C, TN-S, TN, TT and IT Systems<br />

• All-in-one modular protection unit, ready for connection<br />

• Rare-gas-filled spark gap, hermetically sealed<br />

• Discharge capacity up to 100 kA (10/350µs)<br />

• High quenching of follow-on short-circuit currents<br />

• High insulation resistance<br />

• Protection level up to 4 kV<br />

• High TOV resistance<br />

• Maximum operational availability<br />

• V-wiring with multi-functional terminals<br />

• No blow-out vents, thus, not requiring any safety<br />

clearance to other installations<br />

• No leakage currents, thus, allowing installation<br />

upstream of power meters<br />

• Optional remote signalling contact (FM) requiring no<br />

additional space<br />

• Operates independently of atmospheric air pressure<br />

and ambient humidity<br />

Multi-pole lightning current arrester for the protection of lowvoltage<br />

consumers’ installations in business and residential<br />

areas against surges caused by lightning or switching actions<br />

in the network.<br />

The arresters can be installed at the transition 0 A to 1 according<br />

to the lightning protection zones concept.<br />

The series PowerPro B (PP B) has the following performance<br />

features: 50 kA (10/350 µs) per pole and 100 kA (10/350 µs) between<br />

N and PE in TT systems respectively. It is classified as<br />

class I (T1) SPD (former category B) with a voltage protection<br />

level of 4 kV between L and PE (or N in TT systems) depending<br />

on the impulse current load.<br />

The SPDs of the series PowerPro B feature a high thermal resistance<br />

and an outstanding discharge capability for lightning<br />

impulse currents of 50 kA (10/350 µs) per pole. Therefore,<br />

they can be applied according to DIN EN 62305 (VDE<br />

0185-305).<br />

The rare-gas-filled combined modular arresters of the series<br />

PowerPro B significantly reduce possible follow-on shortcircuit<br />

currents due to an extremely quick quenching after<br />

equipotential bonding. Therefore, upstream positioned<br />

surge-current protection devices are not triggered.<br />

The SPDs are leakage-current free and protect the earthing<br />

system against dangerous ac-caused corrosion.<br />

Due to their good insulation against earth of 10 GΩ and the<br />

fact that no leakage-current affected varistors (MOV) are<br />

connected in parallel, they even can be placed upstream<br />

of the meter according to the specifications of the German<br />

VDN (TAB 2007).<br />

The modular designed, multi-pole complete units are available<br />

for TN, TN-C, TN-S, TN-C-S, and TT systems according to<br />

IEC (EN, VDE, OEVE, etc.) standards. They are shipped readyto-connect<br />

(on rail). They are also available for IT networks<br />

in country-specific versions with or without neutral conductor<br />

(N).<br />

<strong>Leutron</strong> also offers a special version with a higher operating<br />

voltage. The units can universally be installed at all export<br />

countries with nominal system voltages of 200 to 260 V.<br />

The TT system version discharges the impulse current between<br />

L and N. Between N and PE a <strong>Leutron</strong> summation current<br />

spark gap SumPro with 100 kA (10/350µs) will be applied<br />

which corresponds to the highest lightning protection class<br />

I according to VDE 0185-305 (IEC DIN EN 62305).<br />

With back-up fuses or circuit-breakers of more than 250 A, a<br />

selective back-up fuse (fusible cutout) of max. 250 A has to<br />

be installed to avoid an overload of the IsoPro caused by a<br />

high short-circuit current.<br />

The pre-assembled, two-pole busbars at the terminals allow<br />

a serial V-wiring of the SPD to a back-up fuse up to 125 A.<br />

In the case of single-pole units the individual SPD modules<br />

can optionally be delivered with integrated, non-resetable<br />

thermal sensors (/FM) or (/Pk).<br />

The remote signalling contact (FM or Pk) is connected via a<br />

twisted-pair cable to an integrated plug-type terminal block<br />

of the SPD.<br />

The latching hooks per pole on both sides of the SPD allow<br />

for an installation on a 35 mm DIN rail, even under difficult<br />

mounting conditions inside the distributor.<br />