Power Engineering<br />
Class II (T2) Surge Arresters, leakage-current free<br />
EnerPro 280Tr<br />
• Very space-saving installation!<br />
• Only 1 modular width instead of 2<br />
• Two-pole high performance surge protector for<br />
230/400 V<br />
• Function control indication via LED<br />
• 2+1 circuit<br />
The SPD modules have thermal disconnection devices per<br />
pole, which respond if, due to an overload, the partial lightning<br />
current through the metal oxide varistor exceeds a certain<br />
value. In this case the green LED extinguishes and the optional<br />
thermal sensor with remote contact (normally closed)<br />
opens. In order to maintain the surge voltage protection the<br />
SPD has immediately to be replaced.<br />
The thermally triggered, potential-free remote alarm contact<br />
is a hermetically sealed switch to eliminate environmental<br />
influences and to guarantee the highest possible security.<br />
For security reasons it is designed as a normally closed contact<br />
(NC).<br />
The MOV and the expulsion-type spark gap are connected<br />
in series to avoid heating and, thus, ageing in the state of<br />
rest. Therefore, a considerable increase in life expectancy is<br />
reached. Thus, the protection modules do not need to be<br />
pluggable.<br />
The SPD is equipped with a reliable LED function display in<br />
place of a mechanical display.<br />
The LED has a dual function as indicator for the varistor function<br />
and as voltage monitor. Therefore, a proper connection<br />
and function of the SPD is indicated during installation. Additionally,<br />
an extinguished LED during operation indicates a<br />
malfunction.<br />
The optional remote alarm contacts are placed in the housing.<br />
For the electrical connection twisted cables are attached<br />
to screw-type terminals at a terminal fixing of the SPD.<br />
Since this SPD version is leakage current-free, the earthing<br />
system is protected against dangerous ac-caused corrosion<br />
and the earth leakage circuit-breaker will not be activated<br />
by leakage currents.<br />
Versions with additional gas-discharge spark gaps do not<br />
interfere with the function of permanently installed insulation<br />
monitoring devices and earth leakage circuit-breakers.<br />
This compact SPD with a modular width of only 1 MW is designed<br />
for single-phase TN systems with backup fuses up to<br />
125 A. A single protection unit can protect two conductors<br />
(against PE or N) or one conductor and the neutral conductor<br />
(against PE).<br />
The arrester has only half the width of standard protective<br />
devices.<br />
The EnerPro 280Tr is equipped with a thermal disconnection<br />
device, which is triggered if due to an overload (high leakage<br />
currents) the varistor temperature rises too much.<br />
In this case the green function control indication extinguishes<br />
and the optional remote contact opens. In order to maintain<br />
the surge voltage protection the SPD has immediately<br />
to be replaced.<br />
In 230 V ac networks the optional potential-free remote contact<br />
(FM) can be updated by an additional acoustic/optical<br />
signalling device UAS 230-Tr with test key (Item no. 35 10 30),<br />
even at a later point in time.<br />