02.05.2014 Views

Search - OECD Nuclear Energy Agency

Search - OECD Nuclear Energy Agency

Search - OECD Nuclear Energy Agency

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Figure 4. Temperature and velocity distribution of the single window<br />

Table 1. Maximum temperature for the single window<br />

Bottom inlet velocity<br />

(m/s)<br />

Max. temp.<br />

( o C)<br />

1.1 1.35 1.5 2.0<br />

2 277 2 086 2 003 1 808<br />

The coolant flowing direction is x-directional co-ordinate and the vertical direction of the coolant<br />

flowing is the y-directional co-ordinate. The spacing of the y-directional cells is 1 mm. We used the<br />

same heat generation rates for the inner and outer windows as shown in Figure 2. The heat transfer of<br />

the lower surface of lower window is treated by the heat transfer coefficient obtained by the<br />

calculation of the single window.<br />

Maximum temperatures in the double windows are presented in Table 2. The maximum<br />

temperature in the inner window reaches 1 580 o C. This value is higher than the window melting<br />

temperature. The inlet velocity of the Pb-Bi coolant flowing in the narrow channel must be larger than<br />

6 m/s. As a result, the maximum temperature in the lower window reaches 1 077 o C for a 1.1 m/sec<br />

bottom inlet velocity of the single window and 927 o C for a 2.0 m/s bottom inlet velocity.<br />

Table 2. Maximum temperature for the double window<br />

Bottom inlet velocity<br />

(m/s)<br />

Upper window<br />

( o C)<br />

Lower window<br />

( o C)<br />

1.1 1.35 1.5 2.0<br />

1 580 1 580 1 580 1 580<br />

1 077 1 027 997 927<br />