PC-COM<br />

The COM interface used by <strong>the</strong> Windows driver must be set.<br />

CAN Bus<br />

Address setting <strong>for</strong> diagnostics channel via CAN bus. The setting uses <strong>the</strong> hex data<br />

<strong>for</strong>mat.<br />

Address of <strong>the</strong> 1st CAN telegram: 0x001 to 0x063 or 0x83 to 0x7FF.<br />

Aktivating extended data with CAN bus<br />

Address of <strong>the</strong> 2nd CAN telegram: 0x001 to 0x063 or 0x83 to 0x7FF.<br />

The value must not be <strong>the</strong> same as <strong>the</strong> 1st CAN address.<br />

Cyclic transmission<br />

This option can be used to set <strong>the</strong> <strong>SMX</strong>-system transmission interval in cycles<br />

(1 cycle = 8ms).<br />

Connection dialog<br />

Connect: Starts <strong>the</strong> connection to <strong>the</strong> <strong>SMX</strong>-system<br />

Quit: Cancels an active connection.<br />

<strong>Programming</strong> <strong>Manual</strong> – <strong>SMX</strong> Basic <strong>Module</strong>s 29.10.2009 Page 22 of 183