Note: When editing <strong>the</strong> associated inPort element, <strong>the</strong> connection with <strong>the</strong> start<br />
element is deleted and cannot be restored automatically. It must be subsequently<br />
supplemented manually.<br />
InPort - Signal No. 1<br />
As with <strong>the</strong> inPort elements, this selection list is used to determine <strong>the</strong> inPort to<br />
which <strong>the</strong> button <strong>for</strong> <strong>for</strong> <strong>the</strong> start element is to be connected. This inPort is<br />
internally limited to <strong>the</strong> assignment to a basic module (E0.1 to E0.14). When <strong>the</strong><br />
AlarmReset option is used, no cross-shorting monitoring can be permitted <strong>for</strong> this<br />
inPort. In <strong>the</strong> dialog <strong>the</strong> corresponding input field is fixed to "OFF".<br />
use as AlarmReset (normally open)<br />
With this option currently present malfunctions (= ALARM) or triggered monitoring<br />
functions can be reset through a connected normally open contact.<br />
The following table shows an overview of all monitoring functions and <strong>the</strong>ir<br />
acknowledgement in triggered state.<br />
Monitoring functions<br />
SEL<br />
SLP<br />
SCA<br />
SSX<br />
SLI<br />
SDI<br />
SLS<br />
SOS<br />
SAC<br />
PDM<br />
ECS<br />
Acknowledgement required<br />
Yes<br />
Yes<br />
No<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
Yes<br />
No<br />
No<br />
Yes<br />
Note<br />
The same functionality is achieved when using <strong>the</strong> "Function" button of <strong>the</strong><br />
basic <strong>SMX</strong> module.<br />
Error messages of type "FatalError" require a restart of <strong>the</strong> basic <strong>SMX</strong><br />
module.<br />
The alarm reset input can be operated with 24V continuous voltage and is<br />
edge triggered.<br />
<strong>Programming</strong> <strong>Manual</strong> – <strong>SMX</strong> Basic <strong>Module</strong>s 29.10.2009 Page 50 of 183