Real Time Clock Control<br />
The cpuModule is equipped with a Real Time Clock (RTC) which provides system date and time<br />
functions, and also provides 128 non-volatile memory locations. The contents of these memory locations<br />
are retained whenever an external backup battery is connected, whether or not system power<br />
is connected.<br />
You may access the RTC date, time, and memory using an index and data register at I/O addresses<br />
70h and 71h. Address 70h is the Index register. It must be written with the number of the register to<br />
read or write. Refer to the map below for valid choices for the index. Data is then written to or read<br />
from the selected register by writing or reading (respectively) the data register at address 71h.<br />
Do not change values stored in the RTC registers listed as<br />
RESERVED in the table below. Doing so will interfere with proper<br />
cpuModule operation.<br />
Registers of the Real Time Clock are shown below:.<br />
Real Time Clock Registers<br />
Registers<br />
(hex)<br />
Registers<br />
(decimal)<br />
Number of<br />
Bytes<br />
Function<br />
00h 0 1 BCD Seconds<br />
02h 2 1 BCD Minutes<br />
04h 4 1 BCD Hours<br />
06h 6 1 Day of week<br />
07h 7 1 Day of month<br />
08h 8 1 Month<br />
09h 9 1 Year<br />
0A-31h 10-49 40 RESERVED- Do not modify!<br />
32h 50 1 BCD Century<br />
33-3Fh 51-63 13 RESERVED - Do not modify!<br />
40-7Fh 64-127 64 User RAM<br />
RTC access is illustrated in the following QuickBasic program fragment:<br />
input "Enter address to write:", i%<br />
input "Enter value to write:", j%<br />
output &h70, i%<br />
output &h71, j%<br />
output &h70,i%<br />
j% = input (&h71)<br />
print "Read back value ";i%;" at address ";j%<br />
89