erratic operation excessive bus loading reduce number of PC/104 modules in<br />

stack;<br />

remove termination components from bus<br />

signals;<br />

remove any power supply bus terminations<br />

power supply noise<br />

power supply limiting<br />

temperature too high<br />

examine power supply output with oscilloscope;<br />

glitches below 4.75Vdc will trigger<br />

a reset; add bypass caps<br />

examine power supply output with oscilloscope;<br />

check for voltage drop below 4.75V<br />

when hard drive or floppy drive starts; add<br />

bypass caps<br />

add fan, processor heatsink, or other cooling<br />

device(s)<br />

See 686GX233 Thermal Management.<br />

memory address conflict<br />

check for two hardware devices (e.g.<br />

Ethernet, SSD, Arcnet, PCMCIA) trying<br />

to use the same memory address<br />

check for two software devices (e.g.<br />

EMM386, PCMCIA drivers, etc.) trying to<br />

use the same memory addresses<br />

check for hardware and software devices<br />

trying to use the same memory address<br />

check for an address range shadowed (see<br />

Advanced Setup screen) while in use by<br />

another hardware or software device<br />

I/O address conflict<br />

check for another module trying to use I/O<br />

addresses reserved for the cpuModule between<br />

010h and 01Fh<br />

keyboard does not work<br />

Windows 3.1x installation<br />

program hangs<br />

keyboard interface damaged<br />

by misconnection<br />

wrong keyboard type<br />

smartdrive enabled<br />

check for two modules (e.g. dataModules,<br />

PCMCIA cards, Ethernet) trying to use the<br />

same I/O addresses<br />

check if keyboard LEDs light<br />

verify keyboard is an 'AT' type or switch to<br />

'AT' mode<br />

remove smartdrive command from config.sys,<br />

reboot, run install program<br />

floppy drive light always on cable misconnected check for floppy drive cable connected<br />

backwards<br />