<strong>Software</strong> Fixes in <strong>Release</strong> E.06.xx through E.10.xx<br />

<strong>Release</strong> E.10.04<br />

■<br />

Config (PR_1000246102) - The show config command indicates a configuration file named<br />

"config" already exists.<br />

<strong>Release</strong> E.10.04<br />

Problems Resolved in <strong>Release</strong> E.10.04<br />

■<br />

■<br />

■<br />

Console/TELNET (PR_1000278912) - The 5300xl console will lock up when connected<br />

via the console port and attempting to establish a TELNET connection into a remote switch.<br />

Meshing (PR_1000218463) - If a mesh link goes down and a redundant (xSTP) link<br />

external to the mesh goes into a forwarding state, connectivity across the mesh may be lost<br />

for a previously learned MAC address.<br />

SNMP (PR_1000003378) - SNMP switch time may drift with event log updates occurring<br />

every 1.5 hours.<br />

<strong>Release</strong> E.10.05<br />

Problems Resolved in <strong>Release</strong> E.10.05<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

ACL (PR_1000283338) - The commands "show port-access mac" and "show port-access<br />

web" incorrectly display the number of clients authenticated.<br />

Crash (PR_1000282444) - When enabling OSPF MD5, the switch may crash with a message<br />

similar to:<br />

<strong>Software</strong> exception at exception.c:373 -- in 'mSess1’.<br />

mini-GBIC (PR_1000283081) — After hot-swapping a mini-GBIC, the Link and Activity<br />

LEDs do not turn on.<br />

mini-GBIC (PR_1000283082) — Some Gigabit LX mini-GBICs may fail when the mini-<br />

GBIC switch module is hot-swapped.<br />

mini-GBIC (PR_1000283084) — When a mini-GBIC is removed from the module, the Fault<br />

and Port LEDs will continue to flash.<br />

RADIUS (PR_1000285456) — If more than one RADIUS assigned vendor specific attribute<br />

(including Port-cos, rate-limiting-ingress, or ACLs) is configured with a non-vendor specific<br />

attribute, only the first vendor specific attribute may be recognized by switch.<br />

Web UI/mini-GBIC (PR_1000279145) — When using the web user interface, the switch<br />

will not display an indication of the Gigabit 1000Base-T mini-GBIC (J8177B) from the<br />

Configuration tab "Device View".<br />