<strong>Software</strong> Fixes in <strong>Release</strong> E.06.xx through E.10.xx<br />
<strong>Release</strong> E.10.25<br />
IDM (PR_1000310201) — The Switch fails to de-authenticate an 802.1X client after a corrupted<br />
configuration file is received from a RADIUS server.<br />
Mini-GBIC (PR_1000308653) — On ProCurve Switch xl 16-port 10/100/1000 Module (J4907A), a<br />
dual-personality port will stop working after a mini-GBIC is hot-swapped out.<br />
RSTP (PR_1000309683) — Temporary routing or switching problems may occur after RSTP is<br />
disabled.<br />
<strong>Release</strong> E.10.25<br />
Problems Resolved in <strong>Release</strong> E.10.25 (Never released)<br />
Connection Rate Filter (PR_1000310834) — Memory leak found during ProCurve stress testing.<br />
A user may see a switch reboot or halt if using the CRF traps and runs the switch for a sufficiently<br />
long time between reboots.<br />
<strong>Release</strong> E.10.26<br />
Problems Resolved in <strong>Release</strong> E.10.26 (Never released)<br />
■<br />
SNMP Traps (PR_1000285195) — Switch does not save the option to disable a<br />
“Link up/down” SNMP trap after a switch reboot.<br />
<strong>Release</strong> E.10.27<br />
Problems Resolved in <strong>Release</strong> E.10.27<br />
■<br />
■<br />
■<br />
■<br />
■<br />
Crash (PR_1000282359) — When searching the log for an extremely long string, the switch<br />
may crash with a bus error similar to:<br />
PPC Bus Error exception vector 0x300: Stack Frame=0x0c8c1a70 HW Addr=0x6a73616c<br />
IP=0x007d3bc0 Task='mSess1' Task ID=0xc8c2920 fp: 0x6b61736a sp:0x0c8c1b30<br />
lr:0x007d3b28.<br />
LLDP (PR_1000310666) — The command "show LLDP" does not display information<br />
learned from CDPv2 packets.<br />
MSTP Enhancement (PR_1000317990) — Implemented new CLI commands, "span<br />
legacy-mode" and "span legacy-path-cost".<br />
RSTP (PR_1000307278) — Replacing an 802.1D bridge device with an end node (non-STP<br />
device) on the same Switch port, can result in the RSTP Switch sending TCNs.<br />
Web UI (PR_1000305944) — The Port Configuration screen display is blank due to a Java<br />
error when using Windows Explorer 6.0.<br />