<strong>Software</strong> Fixes in <strong>Release</strong> E.06.xx through E.10.xx<br />

<strong>Release</strong> E.10.33<br />

■<br />

■<br />

■<br />

■<br />

DHCP Enhancement (PR_1000311957) — Added option to configure the switch to use<br />

the management VLAN IP address in the Option 82 field for all DHCP requests received from<br />

various VLANs. For details, see “DHCP Option 82: Using the Management VLAN IP Address<br />

for the Remote ID” on page 14<br />

Enhancement (PR_1000287679) — Fast Boot CLI & SNMP Implementation. For details<br />

see “Using Fastboot To Reduce Boot Time” on page 14.<br />

ICMP (PR_1000235905) — Switch does not send a 'destination unreachable' response<br />

message when trying to access an invalid UDP port.<br />

Menu (PR_1000318531) — When using the 'Menu' interface, the Switch hostname may be<br />

displayed incorrectly.<br />

<strong>Release</strong> E.10.33<br />

Problems Resolved in <strong>Release</strong> E.10.33 (Never released)<br />

■<br />

■<br />

■<br />

Counters (PR_1000321097) — Drop counters are displaying incorrect information.<br />

Counters (PR_1000321476) — SNMP counter may display incorrect information.<br />

Enhancement (PR_1000330704) — Added RADIUS Command Authorization and<br />

Accounting for the Command Line Interface.<br />

<strong>Release</strong> E.10.34<br />

Problems Resolved in <strong>Release</strong> E.10.34 (Not a general release)<br />

■<br />

■<br />

SSHv2 (PR_1000320822) — The Switch does not generate SSHv2 keys and may crash with<br />

a message similar to:<br />

TLB Miss: Virtual Addr=0x00000000 IP=0x80593a30 Task='swInitTask' Task<br />

ID=0x821ae330 fp:0x00000000 sp:0x821adfb8 ra:0x800803f0 sr:0x1000fc01.<br />

Module Fault (PR_1000331147) — Switch modules J9001A (Switch xl Wireless EDGE<br />

Services Module) and J8162A (Switch xl Access Controller Module) will fault if Fast Boot is<br />

enabled and the log will report the following Major event:<br />

"HPESP: Access Controller XL Module x: incompatible BIOS version".<br />

<strong>Release</strong> E.10.35<br />

Problems Resolved in <strong>Release</strong> E.10.35 (Not a general release)<br />

55