<strong>Software</strong> Fixes in <strong>Release</strong> E.06.xx through E.10.xx<br />

<strong>Release</strong> E.10.36<br />

■<br />

■<br />

■<br />

■<br />

Event Log (PR_1000323203) — MD5 hash mismatch log messages are triggered with<br />

VLAN toggles: "OSPF Drop pkt from:xxx.xxx.xxx.xxx md5-key-id:1 reason: md5 hash mismatch".<br />

IDM (PR_1000334365) — Using EAP/802.1x with IDM ACLs can result in memory leaks.<br />

OSPF (PR_1000323201) — OSPF does not always redistribute connected networks when<br />

MD5 authentication is enabled and connected subnets or VLANs are toggled.<br />

Web UI (PR_1000302713) — When using the web user interface and a large amount of<br />

stacking interactions occur, portions of the information from the stack commander may no<br />

longer appear.<br />

<strong>Release</strong> E.10.36<br />

Problems Resolved in <strong>Release</strong> E.10.36 (not a general release)<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

CLI (PR_1000322029) — The command "show vlans" does not display data correctly in<br />

the status field.<br />

Config/Security (PR_1000334412) — Operator level can save Manager privilege level<br />

changes to the configuration.<br />

Log (PR_1000323790) — The switch detects a counterfeit mini-GBIC as a port self test<br />

failure and subsequently disables the link.<br />

sFlow Enhancement (PR_1000337714) — Added new "show sflow" commands to the<br />

CLI. For details, see “SFlow Show Commands” on page 17.<br />

STP/RSTP/MSTP (PR_1000330532) — Improved the "show" commands display of STP<br />

ports detail information to assist in monitoring and troubleshooting the spanning tree<br />

protocol.<br />

Web UI (PR_1000331431) — The QoS Configuration Tab is not working correctly when<br />

using the Web User Interface.<br />

<strong>Release</strong> <strong>E.10.37</strong><br />

Problems Resolved in <strong>Release</strong> <strong>E.10.37</strong><br />

■<br />

■<br />

CLI (PR_1000330553) — Garbage characters displayed in "show snmp-server" cli output.<br />

Menu (PR_1000308364) — In the Menu's Switch Configuration->System Information<br />

screen, the “SNTP Poll Interval” field is missing the poll interval descriptor.<br />