COFFEtek Ltd<br />

MENU OPTIONS<br />

Ingredient Times<br />

8. INGREDIENT TIMES provides access to a set of submenus, which allow modification of the<br />

parameters controlling the recipe and dispensing of individual drinks. The actual content of the<br />

submenu is dependent on the configuration of the machine. That is, for example, a Geneva Instant<br />

Hot version will have different drinks in its INGREDIENT TIMES submenu to a Double Fresh Brew<br />

version fitted with a carbonator. In general the entries of the INGREDIENT TIMES menu will<br />

consist only of the drinks available on that particular configuration of machine. The Geneva range<br />

has a number of pre-defined configurations. For each configuration each selection button is<br />

associated with a particular drink. This association is predefined for each configuration, but can be<br />

modified within narrow limits using the EDIT DRINK MAP menu.<br />

Note: Changes to the menu will lead to initialisation of all machine.<br />

9. For each selection a user with manager level access is granted a limited range adjustment on a<br />

subset of the parameters. This allows the site-based personnel to perform minor taste profile<br />

modifications without the need to call an engineer. The limited range adjustment is implemented<br />

as a multiplying scale factor of between 75% and 125%. In manager’s mode the limited range of<br />

adjustment permitted is displayed as a signed value between –25% and +25% and can be<br />

changed in 5% increments. For example, the limited range strength control for the coffee<br />

ingredient of an Espreschoc selection, which has had its coffee ingredient increased by 5% would<br />

appear to a manager level user as:<br />

OP: COFFEE MOD<br />

+5%<br />

When viewed with engineer level access this would appear as:<br />

OP: COFFEE MOD<br />

105<br />

In each case the same parameter is being viewed.<br />

<strong>GENEVA</strong> Issue 3 06/08/2008 28