COFFEtek Ltd<br />
MENU OPTIONS<br />
Ingredient Times<br />
8. INGREDIENT TIMES provides access to a set of submenus, which allow modification of the<br />
parameters controlling the recipe and dispensing of individual drinks. The actual content of the<br />
submenu is dependent on the configuration of the machine. That is, for example, a Geneva Instant<br />
Hot version will have different drinks in its INGREDIENT TIMES submenu to a Double Fresh Brew<br />
version fitted with a carbonator. In general the entries of the INGREDIENT TIMES menu will<br />
consist only of the drinks available on that particular configuration of machine. The Geneva range<br />
has a number of pre-defined configurations. For each configuration each selection button is<br />
associated with a particular drink. This association is predefined for each configuration, but can be<br />
modified within narrow limits using the EDIT DRINK MAP menu.<br />
Note: Changes to the menu will lead to initialisation of all machine.<br />
9. For each selection a user with manager level access is granted a limited range adjustment on a<br />
subset of the parameters. This allows the site-based personnel to perform minor taste profile<br />
modifications without the need to call an engineer. The limited range adjustment is implemented<br />
as a multiplying scale factor of between 75% and 125%. In manager’s mode the limited range of<br />
adjustment permitted is displayed as a signed value between –25% and +25% and can be<br />
changed in 5% increments. For example, the limited range strength control for the coffee<br />
ingredient of an Espreschoc selection, which has had its coffee ingredient increased by 5% would<br />
appear to a manager level user as:<br />
OP: COFFEE MOD<br />
+5%<br />
When viewed with engineer level access this would appear as:<br />
OP: COFFEE MOD<br />
105<br />
In each case the same parameter is being viewed.<br />
<strong>GENEVA</strong> Issue 3 06/08/2008 28