WATER SYSTEM<br />

23. The cold water mains supply enters the machine via a double-solenoid operated inlet valve<br />

at the rear of the cabinet. This valve controls the flow of water to the unit’s hot water tank.<br />

If an optional cold drink system is fitted, a separate inlet valve is used to connect it to the<br />

mains water supply. In this eventuality a special ‘Y’ shaped mains water supply hose is<br />

required.<br />

Hot Water System<br />

24. Water is supplied via the Hot Inlet valve to the heater tank where it is heated to the required<br />

temperature by a heating element in the tank. Water temperature is controlled by a<br />

combined temperature and level probe assembly in the tank which causes the supply to the<br />

heater to be removed when the preset temperature is reached. The probe assembly also<br />

acts as a level sensor, causing the Hot Inlet valve to open when the water in the tank falls<br />

below a preset level. The probe (i.e. the input device) is monitored by the Controller Board,<br />

and the Water Heater and Hot Inlet valve (i.e. the output devices) are controlled by the DC<br />

RIO Board in response to signals from the Controller Board.<br />

25. Depending on the type of hot drink selected, hot water from the heater tank is fed via<br />

solenoid operated dispense valves to the appropriate mixing bowl or Brewer Unit container.<br />

Ingredients and water are mixed in exact quantities in the mixing bowl and then directed to<br />

the dispense head. Similarly, water and ingredient are brewed in exact amounts in the<br />

Brewer Unit and then directed to the dispense head.<br />

26. Resettable cut-out sensors, mounted on the boiler overfill tube, cuts off the electrical supply<br />

to the tank heater circuit if the water in the tank starts to boil. Additionally, if the fluid level in<br />

the overflow waste bucket rises above a preset level, it is detected by a level probe and<br />

reported to the Controller Board, which responds by closing the inlet valve via the DC RIO<br />

Board and rendering the machine inoperable.<br />

Cold Water System<br />

27. Water is supplied from the Cold Inlet valve to the chiller or carbonator unit (if fitted) via a<br />

pressure regulator. The chiller/carbonator provides either cold still water or cold carbonated<br />

water (carbonator only). The selected type of water (still or carbonated) is controlled by<br />

solenoid operated dispense valves. Flavoured syrup, if available, is added to the drink by<br />

means of oscillating pumps.<br />