GENEVA - Vending Machines
GENEVA - Vending Machines
GENEVA - Vending Machines
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
COFFEtek Ltd<br />
SOUP<br />
* E indicates engineer access level<br />
M indicates manager access level<br />
Parameter Name Function Units<br />
Level<br />
See *<br />
SOUP TIME Auger run time for Soup ingredient .1 s E<br />
WATER TIME Soup water dispense valve open duration .1s E<br />
MIXER TIME Soup mixer motor run time .1s E<br />
MIXER START Soup mixer motor start time referenced to t=0 .1s E<br />
OP: Soup Mod<br />
OP: Water Mod<br />
Manager level control applied to SOUP TIME<br />
The actual soup auger run time will be:<br />
SOUP TIME x OP: Soup Mod /100<br />
Manager level control applied to WATER TIME<br />
The actual dispense valve open time will be<br />
WATER TIME x OP: Water Mod/100<br />
% E,M<br />
% E,M<br />
LEMON (STILL DRINK 1)<br />
* E indicates engineer access level<br />
M indicates manager access level<br />
Parameter Name Function Units<br />
Level<br />
See *<br />
WATER TIME Chilled water dispense valve open duration .1s E<br />
SYRUP 1 TIME Syrup pump one operating time .1s E<br />
OP: Water Mod<br />
OP: Syrup 1 time<br />
Manager level control applied to WATER TIME<br />
The actual valve opening time will be:<br />
WATER TIME x OP: Water Mod /100<br />
Manager level control applied to SYRUP 1 TIME<br />
The actual syrup pump run time will be:<br />
SYRUP 1 TIME x OP: Syrup 1 time /100<br />
% E,M<br />
% E,M<br />
ORANGE (STILL DRINK 2)<br />
* E indicates engineer access level<br />
M indicates manager access level<br />
Parameter Name Function Units<br />
Level<br />
See *<br />
WATER TIME Chilled water dispense valve open duration .1s E<br />
SYRUP 2 TIME Syrup pump two operating time .1s E<br />
OP: Water Mod<br />
OP: Syrup 2 time<br />
Manager level control applied to WATER TIME<br />
The actual valve opening time will be:<br />
WATER TIME x OP: Water Mod /100<br />
Manager level control applied to SYRUP 2 TIME<br />
The actual syrup pump run time will be:<br />
SYRUP 2 TIME x OP: Syrup 2 time /100<br />
% E,M<br />
% E,M<br />
39 06/08/2008 Issue 3 <strong>GENEVA</strong>