COFFEtek Ltd<br />

SOUP<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

SOUP TIME Auger run time for Soup ingredient .1 s E<br />

WATER TIME Soup water dispense valve open duration .1s E<br />

MIXER TIME Soup mixer motor run time .1s E<br />

MIXER START Soup mixer motor start time referenced to t=0 .1s E<br />

OP: Soup Mod<br />

OP: Water Mod<br />

Manager level control applied to SOUP TIME<br />

The actual soup auger run time will be:<br />

SOUP TIME x OP: Soup Mod /100<br />

Manager level control applied to WATER TIME<br />

The actual dispense valve open time will be<br />

WATER TIME x OP: Water Mod/100<br />

% E,M<br />

% E,M<br />

LEMON (STILL DRINK 1)<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

WATER TIME Chilled water dispense valve open duration .1s E<br />

SYRUP 1 TIME Syrup pump one operating time .1s E<br />

OP: Water Mod<br />

OP: Syrup 1 time<br />

Manager level control applied to WATER TIME<br />

The actual valve opening time will be:<br />

WATER TIME x OP: Water Mod /100<br />

Manager level control applied to SYRUP 1 TIME<br />

The actual syrup pump run time will be:<br />

SYRUP 1 TIME x OP: Syrup 1 time /100<br />

% E,M<br />

% E,M<br />

ORANGE (STILL DRINK 2)<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

WATER TIME Chilled water dispense valve open duration .1s E<br />

SYRUP 2 TIME Syrup pump two operating time .1s E<br />

OP: Water Mod<br />

OP: Syrup 2 time<br />

Manager level control applied to WATER TIME<br />

The actual valve opening time will be:<br />

WATER TIME x OP: Water Mod /100<br />

Manager level control applied to SYRUP 2 TIME<br />

The actual syrup pump run time will be:<br />

SYRUP 2 TIME x OP: Syrup 2 time /100<br />

% E,M<br />