COFFEtek Ltd<br />

CHOCOMILK<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

CHOCOLATE START Start time for the chocolate components of the drink .1s E<br />

referenced to t=0<br />

CHOCOLATE TIME Auger run time for Chocolate ingredient .1s E<br />

TOPPING START<br />

Start time for the topping components of the drink<br />

.1s E<br />

referenced to t=0<br />

TOPPING TIME Auger run time for Topping ingredient .1s E<br />

WATER TIME Topping/chocolate dispense valve open duration .1s E<br />

MIXER TIME Chocolate mixer motor run time .1s E<br />

OP: Topping Mod<br />

OP: Chocolate Mod<br />

OP: Water Mod<br />

Manager level control applied to TOPPING TIME<br />

The actual topping auger run time will be:<br />

TOPPING TIME x OP: Topping Mod /100<br />

Manager level control applied to CHOCOLATE TIME<br />

The actual chocolate auger run time will be:<br />

CHOCOLATE TIME x OP: Chocolate Mod /100<br />

Manager level control applied to WATER TIME<br />

The actual dispense valve open time will be:<br />

WATER TIME x OP: Water Mod /100<br />

% E,M<br />

% E,M<br />

% E,M<br />

CHOCOLATE<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

CHOCOLATE TIME Auger run time for Chocolate ingredient .1s E<br />

WATER TIME Chocolate dispense valve open duration .1s E<br />

MIXER START Chocolate mixer start time .1s E<br />

MIXER TIME Chocolate mixer motor run time .1s E<br />

OP: Chocolate Mod<br />

OP: Water Mod<br />

Manager level control applied to CHOCOLATE TIME<br />

The actual chocolate auger run time will be:<br />

CHOCOLATE TIME x OP: Chocolate Mod /100<br />

Manager level control applied to WATER TIME<br />

The actual dispense valve open time will be:<br />

WATER TIME x OP: Water Mod /100<br />

% E,M<br />

% E,M<br />

<strong>GENEVA</strong> Issue 3 06/08/2008 30