GENEVA - Vending Machines
GENEVA - Vending Machines
GENEVA - Vending Machines
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
COFFEtek Ltd<br />
HOT WATER<br />
* E indicates engineer access level<br />
M indicates manager access level<br />
Parameter Name Function Units<br />
Level<br />
See *<br />
HOT WATER TIME Hot water dispense valve open duration .1s E<br />
OP: Hot Water Mod<br />
Manager level control applied to HOT WATER TIME<br />
The actual valve opening time will be:<br />
HOT WATER TIME x OP: Water Mod /100<br />
% E,M<br />
FRESH BREW TEA<br />
* E indicates engineer access level<br />
M indicates manager access level<br />
Parameter Name Function Units<br />
Level<br />
See *<br />
TEA WATER TIME Tea water dispense valve open duration .1s E<br />
SUGAR WATER TIME Milk/Sugar dispense valve opening time if optional<br />
.1 s E<br />
ingredient selected. This will be deducted from the TEA<br />
WATER TIME if so used.<br />
TEA TIME Auger run time for tea ingredient .1s E<br />
TEA ADJUSTMENT Increment applied to tea auger run time when strong .1 s E<br />
selected<br />
TEA MIXER START Mixer start time for the optional milk/sugar component .1 s E<br />
That is the milk/sugar mixer start time ref t=0<br />
TEA MIXER TIME Mixer run time for the optional milk/sugar component .1 s E<br />
SUGAR TIME Auger run time for optional ingredient if selected .1 s E<br />
SUGAR ADJUSTMENT Increment applied to sugar auger run time when extra .01 s E<br />
sugar selected<br />
MILK TIME Auger run time for optional ingredient if selected .01 s E<br />
MILK ADJUSTMENT<br />
PAUSE TIME<br />
DRAIN TIME<br />
OP: Sugar Mod<br />
OP: Milk Mod<br />
OP: Tea Mod<br />
OP: Water Mod<br />
Increment applied to milk auger run time when extra milk<br />
selected<br />
Delay between first dose of water through brew chamber<br />
and the second dose<br />
Time to allow tea to drain from the brew chamber before<br />
allowing the head to move<br />
Manager level control applied to SUGAR TIME<br />
The actual sugar auger run time will be:<br />
SUGAR TIME x OP: Sugar Mod /100<br />
Manager level control applied to MILK TIME<br />
The actual milk auger run time will be:<br />
MILK TIME x OP: Milk Mod /100<br />
Manager level control applied to TEA TIME<br />
The actual tea auger run time will be:<br />
TEA TIME x OP: Tea Mod /100<br />
Manager level control applied to water times<br />
The actual dispense valve open times will be:<br />
x OP: Water Mod/100<br />
.1 s E<br />
.1s E,M<br />
.1s E,M<br />
% E,M<br />
% E,M<br />
% E,M<br />
% E,M<br />
41 06/08/2008 Issue 3 <strong>GENEVA</strong>