COFFEtek Ltd<br />

HOT WATER<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

HOT WATER TIME Hot water dispense valve open duration .1s E<br />

OP: Hot Water Mod<br />

Manager level control applied to HOT WATER TIME<br />

The actual valve opening time will be:<br />

HOT WATER TIME x OP: Water Mod /100<br />

% E,M<br />

FRESH BREW TEA<br />

* E indicates engineer access level<br />

M indicates manager access level<br />

Parameter Name Function Units<br />

Level<br />

See *<br />

TEA WATER TIME Tea water dispense valve open duration .1s E<br />

SUGAR WATER TIME Milk/Sugar dispense valve opening time if optional<br />

.1 s E<br />

ingredient selected. This will be deducted from the TEA<br />

WATER TIME if so used.<br />

TEA TIME Auger run time for tea ingredient .1s E<br />

TEA ADJUSTMENT Increment applied to tea auger run time when strong .1 s E<br />

selected<br />

TEA MIXER START Mixer start time for the optional milk/sugar component .1 s E<br />

That is the milk/sugar mixer start time ref t=0<br />

TEA MIXER TIME Mixer run time for the optional milk/sugar component .1 s E<br />

SUGAR TIME Auger run time for optional ingredient if selected .1 s E<br />

SUGAR ADJUSTMENT Increment applied to sugar auger run time when extra .01 s E<br />

sugar selected<br />

MILK TIME Auger run time for optional ingredient if selected .01 s E<br />

MILK ADJUSTMENT<br />

PAUSE TIME<br />

DRAIN TIME<br />

OP: Sugar Mod<br />

OP: Milk Mod<br />

OP: Tea Mod<br />

OP: Water Mod<br />

Increment applied to milk auger run time when extra milk<br />

selected<br />

Delay between first dose of water through brew chamber<br />

and the second dose<br />

Time to allow tea to drain from the brew chamber before<br />

allowing the head to move<br />

Manager level control applied to SUGAR TIME<br />

The actual sugar auger run time will be:<br />

SUGAR TIME x OP: Sugar Mod /100<br />

Manager level control applied to MILK TIME<br />

The actual milk auger run time will be:<br />

MILK TIME x OP: Milk Mod /100<br />

Manager level control applied to TEA TIME<br />

The actual tea auger run time will be:<br />

TEA TIME x OP: Tea Mod /100<br />

Manager level control applied to water times<br />

The actual dispense valve open times will be:<br />

x OP: Water Mod/100<br />

.1 s E<br />

.1s E,M<br />

.1s E,M<br />

% E,M<br />

% E,M<br />

% E,M<br />

% E,M<br />