COFFEtek Ltd<br />
PARAMETER<br />
POSSIBLE VALUES<br />
(DEFAULT IN BOLD)<br />
SILENT KEYS 0<br />
Keys give audible feedback<br />
1<br />
Keys are silent<br />
TOKEN ONLY 0<br />
Messages appropriate to<br />
coins/card system or free<br />
CHIPPER<br />
/CHIPKNIP<br />
1<br />
Suppress credit display if just<br />
card system fitted<br />
FLUSH ALARM 0<br />
Sound load siren while flushing<br />
WATER SHOT<br />
START<br />
WATER SHOT DUR<br />
1<br />
Messages appropriate to token<br />
only operation<br />
0<br />
Normal display of credit<br />
1<br />
Sound siren quietly while<br />
flushing<br />
(Consult factory before changing)<br />
Time after a fresh coffee dispense cycle ends that a grout clearing<br />
water shot starts.<br />
20 (Consult factory before changing)<br />
Duration in 1/100 seconds that the water shot described above lasts.<br />
BELT WARN TIME 700<br />
Time, in 1/100 seconds, after the pressure sensor should have<br />
reported the coffee brew chamber depressurised but has not, that a<br />
‘New filter belt’ warning is displayed.<br />
BELT FAULT TIME 2000<br />
Time, in 1/100 seconds, after the pressure sensor should have<br />
reported the coffee brew chamber depressurised but has not, that a<br />
‘New filter belt’ fault occurs.<br />
ROTATION LIMIT 100<br />
Time, in 1/100 seconds, after the pressure sensor should have<br />
reported the coffee brew chamber depressurised but has not, that a<br />
flag is set to perform an extra rotation of the brewer at the end of the<br />
next brewer drink cycle.<br />
NO BELT<br />
WARNING<br />
ENG MODE<br />
TIMEOUT<br />
1<br />
Do not display information about<br />
the state of the filter belt on the<br />
user display.<br />
0<br />
Do not automatically exit<br />
engineers mode.<br />
0<br />
Display belt warnings on the user<br />
display.<br />
30 (recommended)<br />
Time in 1/10 seconds after<br />
which, if no key is pressed, exit<br />
from the engineer’s program will<br />
commence.<br />
MAX EXTRA CUPS 2<br />
Number of retries at dispensing a cup before a long delay until next<br />
cup occurs to deter theft.<br />
CURRENCY<br />
0 Don’t display currency symbol.<br />
1 Currency symbol is £.<br />
2 Currency symbol is €.<br />
3 Currency symbol is $.<br />
FREE INPUT 0<br />
Ignore free input.<br />
SECURITY INPUT 0<br />
Ignore security input<br />
SIMPLE MDB<br />
CODES<br />
0<br />
Fully encode products, i.e., send<br />
product code for: Cheap+Own<br />
cup, Cheap No cup, Normal+Own<br />
cup and Normal No cup .<br />
1<br />
Monitor free input.<br />
1<br />
Monitor security input.<br />
1<br />
Go light on product codes.<br />
MDB sends just one number per<br />
selection regardless of price.<br />
N&W card reader fix.<br />
55 06/08/2008 Issue 3 <strong>GENEVA</strong>