Fig. 24<br />
Therefore, when mounting a cast on a <strong>Series</strong> <strong>3000</strong><br />
<strong>Articulator</strong>, it is not necessary to record the intercondylar<br />
width marking designated by the S-M-L markings on the<br />
upper arm of the face-bow.<br />
IV. Removing The <strong>Face</strong>-<strong>Bow</strong> From<br />
The Patient<br />
Fig. 25<br />
Loosen the #8604 Thumb Screw on the nasion relator<br />
assembly <strong>and</strong> slide the nasion relator assembly away<br />
from the patient.<br />
Fig. 26<br />
Have the patient hold both arms of the face-bow <strong>and</strong> loosen<br />
the center thumb screw on top of the face-bow.<br />
Note: If using <strong>Whip</strong> <strong>Mix</strong> metal face-bow, loosen the three<br />
thumb screws located on the top.<br />
Fig. 27<br />
Advise the patient to gently pull the ear pieces out of<br />
his or her ears <strong>and</strong> help the patient carefully remove<br />
the face-bow with his or her mouth open. Now is a<br />
convenient time to take the interocclusal records<br />
necessary to mount the lower cast <strong>and</strong> set the condylar<br />
guidance of the articulator.<br />