Fig. 115<br />
After the right condylar guidance has been recorded, the<br />
condylar guidance should be neutralized as previously<br />
described. Next, the left condylar guidance is adjusted using<br />
the right lateral excursion record <strong>and</strong> repeating the above<br />
procedure.<br />
Fig. 116<br />
Many wish to set the condylar inclination of the articulator<br />
with a protrusive record. To utilize the protrusive record,<br />
first neutralize the condylar inclination <strong>and</strong> progressive side<br />
shift settings. Place the protrusive record on the inverted<br />
upper frame of the articulator <strong>and</strong> gently seat the lower<br />
cast into the protrusive record.<br />
Both condylar elements will have moved away from<br />
the posterior surfaces of their respective condylar guides.<br />
Fig. 117<br />
Using sight <strong>and</strong> touch, rotate the left condylar guide until<br />
the teeth on the left side of the upper cast seat evenly into<br />
the protrusive record, then tighten the #2432 Clamp Knob.<br />
Record the reading <strong>and</strong> repeat the procedure on the right<br />
side. Note: The lateral records are used to determine the<br />
progressive side shift settings.<br />
Fig. 118<br />
The mounted case on a Model 3040 <strong>Articulator</strong>.<br />