REFERENCES<br />
4<br />
4 REFERENCES<br />
4.1 USB-COM AND RS232 PARAMETERS<br />
4.1.1 Handshaking<br />
Hardware handshaking: (RTS/CTS)<br />
<strong>The</strong> RTS line is activated by the decoder before transmitting a character.<br />
Transmission is possible only if the CTS line (controlled by the Host) is active.<br />
Signals at<br />
EIA levels<br />
RTS<br />
TX<br />
Transmitted data<br />
Transmitted data<br />
CTS<br />
Host busy<br />
RTS/CTS handshaking<br />
<strong>Software</strong> handshaking: (XON/XOFF)<br />
During transmission, if the Host sends the XOFF character (13 Hex), the decoder<br />
interrupts the transmission with a maximum delay of one character and only resumes<br />
when the XON character (11 Hex) is received.<br />
Transmitted data<br />
Transmitted data<br />
TX<br />
RX<br />
XOFF<br />
Host busy<br />
XON<br />
Host ready<br />
XON/XOFF handshaking<br />