4<br />
HHD II<br />
4.6.7 Aiming System<br />
This parameter is valid for laser readers and provides a<br />
programmable timeout for the aiming system. If enabled, the scan<br />
line emitted from the reading window is preceded by a red spot<br />
which must illuminate the code center to get the best reading<br />
performance (see figure, ). Once the defined timeout is<br />
reached, the red spot disappears and is followed by the scan line<br />
to start the code scanning.<br />
4.7 DECODING PARAMETERS<br />
CAUTION<br />
<strong>The</strong>se parameters are intended to enhance the decoding capability of<br />
the reader for particular applications. Used incorrectly, they can<br />
degrade the reading performance or increase the possibility of a<br />
decoding error.<br />
4.7.1 Ink-Spread<br />
<strong>The</strong> ink-spread parameter allows the decoding of codes which are not perfectly<br />
printed because the page texture tends to absorb the ink.<br />
4.7.2 Overflow Control<br />
<strong>The</strong> overflow control parameter can be disabled when decoding codes printed on<br />
small surfaces, which don’t allow the use of an overflow space.<br />
This command does not effect code families 2/5, Code 128 and Code 93.<br />
4.7.3 Interdigit Control<br />
<strong>The</strong> interdigit control parameter verifies the interdigit spacing for code families Code<br />
39 and Codabar.<br />
118