4<br />

HHD II<br />

4.9 CONFIGURATION COPY COMMAND<br />

Procedure:<br />

<br />

<br />

Connect the master (correctly configured reader) and the slave (reader to be<br />

configured) together through two RS232 serial interface cables and external<br />

power supply. Accessory cables and power supply are available from your<br />

<strong>Datalogic</strong> distributor to provide this connection.<br />

RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328<br />

Power Supply: PG5<br />

Using the slave device, read the Restore Default barcode and then the RS232<br />

interface barcode from par. 2.1.2 of this manual or from the Quick Reference<br />

<strong>Manual</strong>.<br />

<br />

With the master device, read the <strong>Configuration</strong> Copy barcode below.<br />

Copy <strong>Configuration</strong><br />

Ì$+ZZ0$-*Î<br />

$+ZZ0$-<br />

<strong>The</strong> configuration will be copied from the master to the slave device. <strong>The</strong> slave<br />

device signals the end of the procedure with a series of beeps.<br />

Note: <strong>The</strong> master device can be configured for any interface.<br />