Enter <strong>Configuration</strong><br />
Exit and Save <strong>Configuration</strong><br />
Ì$+;Î DATA FORMAT Ì$-Î<br />
CHARACTER REPLACEMENT<br />
disable character replacement<br />
ÌEO0mÎ<br />
This parameter allows up to three characters to be replaced from the barcode read. <strong>The</strong>se<br />
substitutions are stored in memory. To define each character replacement:<br />
<br />
Read one of the following character replacement codes:<br />
<br />
first character replacement<br />
ÌEO1pÎ<br />
<br />
second character replacement<br />
ÌEO2sÎ<br />
<br />
third character replacement<br />
ÌEO3vÎ<br />
<br />
From the Code Identifier Table in Appendix B, read the Code Identifier for the desired<br />
code family.<br />
0 = character replacement will be effective for all code families.<br />
<br />
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)<br />
which identifies the character to be replaced.<br />
<br />
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)<br />
which identifies the new character to replace.<br />
FF = the character to be replaced will be substituted with no character, that is, it will be<br />
removed from the code.<br />
51