4<br />
HHD II<br />
4.6 READING PARAMETERS<br />
4.6.1 Hand-Held and Stand Operation<br />
<strong>The</strong>se parameter groups allow setting different reading modes for Hand-Held<br />
Operation and Stand Operation:<br />
• <strong>Software</strong>Trigger: the reader is set in FLASH MODE. Code reading takes place<br />
during the flash on time;<br />
• Hardware Trigger: the code reading is started with a trigger press (ON);<br />
• Hardware Trigger Ready: the illuminator is switched ON when the reader sees<br />
a code. It functions as a pointer aiming at the code to be read. <strong>The</strong> reading<br />
phase starts only when the trigger is pressed. In this mode the reader is<br />
automatically set to trigger active level and one read per cycle parameters.<br />
(Only for Hand-Held Operation).<br />
• Automatic: the illuminator is switched ON when the reader sees a code. <strong>The</strong><br />
reading phase starts automatically.<br />
• Always ON: the illuminator/laser is always ON and the reader always ready for<br />
code reading.<br />
4.6.2 Hardware Trigger Signal<br />
This parameter determines how the reader ON state is controlled for readers with<br />
button/trigger when Hardware Trigger is selected:<br />
• trigger level: the reader goes ON when the trigger is pressed and goes OFF<br />
when it is released<br />
• trigger pulse: the reader goes ON at the first trigger press and goes OFF only<br />
at a second press<br />
4.6.3 Trigger-Off Timeout<br />
When this timeout is selected, the reader turns OFF automatically after the desired<br />
period of time.<br />
4.6.4 Reads per Cycle<br />
In general, a reading cycle corresponds to the ON + OFF times of a device. <strong>The</strong><br />
resulting effects of this parameter on code reading depend on other related<br />
configuration conditions. Here are the definitions of ON and OFF times.<br />
116